MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.5c04882

Медицинская библиотека · ACS sensors · 2026

Polymer-free Viscoelastic Microfluidics-Integrated Graphene Transistor Biosensing of Saliva Porphyromonas gingivalis for Periodontitis Diagnosis.

Zhao Ya, Li Hejia, Ye Yulin, Diao Jing, Li Yan, Yang Lei, Yuan Chao, Wei Qin

СтатьяПеревод в очереди

Аннотация

Porphyromonas gingivalis (P. gingivalis) as a keystone pathogen of periodontal diseases has been increasingly associated with periodontitis and systemic comorbidities. The rapid and sensitive detection of P. gingivalis in saliva remains challenging because of the complex salivary matrix and insufficient sample preparation in conventional assays. To address these limitations, we developed an integrated saliva-compatible biosensing platform by combining polymer-free viscoelastic microfluidic pretreatment with an electrolyte-gated graphene field-effect transistor (GFET) biosensor. The microfluidic module exploits saliva's intrinsic viscoelasticity to enable additive-free particle focusing by co-flowing viscoelastic saliva with Newtonian PBS. This self-conditioning generates synergistic inertial and elastic lift forces that laterally separate P. gingivalis from the salivary matrix, achieving 93.8% bacterial recovery and 82.1% protein removal. To enhance measurement reliability on the antibody-functionalized Au side-gate, a reference-gate-based differential calibration strategy was implemented to suppress common-mode interference and environmental drift. With this calibration, the integrated GFET biosensor achieved a limit of detection of 291 CFU/mL over a linear range of 1 × 103-1 × 108 CFU/mL, and the clinical validation demonstrated robust discrimination between periodontitis and healthy controls with a high sensitivity of 94.1%. This integrated biosensor provides a compact, low-consumption, and automation-friendly route for saliva-compatible transistor biosensing and advances practical point-of-care periodontal diagnostics.

Для цитирования: Zhao Ya, Li Hejia, Ye Yulin, Diao Jing, Li Yan, Yang Lei, Yuan Chao, Wei Qin. Polymer-free Viscoelastic Microfluidics-Integrated Graphene Transistor Biosensing of Saliva Porphyromonas gingivalis for Periodontitis Diagnosis.. ACS sensors. 2026. DOI: 10.1021/acssensors.5c04882.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.