Congenital heart disease · 2016
Effect of Balloon:Annulus Ratio on Incidence of Pulmonary Insufficiency Following Valvuloplasty.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pathak Sagar J, Pockett Charissa R, Moore John W, El-Said Howaida G
Аннотация
OBJECTIVE: Pulmonary insufficiency following balloon valvuloplasty for pulmonary valve stenosis has been shown to result in right ventricular dilation, which may necessitate pulmonary valve replacement. This study investigates the consequences of employing a more conservative balloon:annulus ratio of ≤1.2 against the currently used ratios of >1.2. The aim of the study was to evaluate whether a more conservative balloon:annulus ratio would maintain procedural success with adequate relief of the pulmonary valve gradient, while minimizing pulmonic insufficiency.
DESIGN: Procedural data were collected on cases considered for balloon valvuloplasty for congenital pulmonic stenosis at Rady Children's Hospital, San Diego between March 31, 2003 and April 9, 2014. The study includes 98 patients whose median age at the time of procedure was 3.6 months (range: 1 day to 271 months); median follow-up was 15.2 months (range 24 days to 106 months). The subjects were divided into two groups based on their balloon:annulus ratio: ≤1.2 (n = 67) and >1.2 (n = 31).
RESULTS: The difference in pulmonary gradient reduction-the marker of procedural success-was not significant between the two groups (P = .33). Although both groups had an increase in pulmonary valve insufficiency from baseline, the ≤1.2 group had significantly less insufficiency compared to the >1.2 group (P = .008). Reintervention rates were not statistically significant between both groups (P = .89).
CONCLUSION: Performing pulmonary balloon valvuloplasty with a balloon:annulus ratio of ≤1.2 produces significantly less pulmonary insufficiency than a ratio of >1.2 without reducing procedure efficacy.
DESIGN: Procedural data were collected on cases considered for balloon valvuloplasty for congenital pulmonic stenosis at Rady Children's Hospital, San Diego between March 31, 2003 and April 9, 2014. The study includes 98 patients whose median age at the time of procedure was 3.6 months (range: 1 day to 271 months); median follow-up was 15.2 months (range 24 days to 106 months). The subjects were divided into two groups based on their balloon:annulus ratio: ≤1.2 (n = 67) and >1.2 (n = 31).
RESULTS: The difference in pulmonary gradient reduction-the marker of procedural success-was not significant between the two groups (P = .33). Although both groups had an increase in pulmonary valve insufficiency from baseline, the ≤1.2 group had significantly less insufficiency compared to the >1.2 group (P = .008). Reintervention rates were not statistically significant between both groups (P = .89).
CONCLUSION: Performing pulmonary balloon valvuloplasty with a balloon:annulus ratio of ≤1.2 produces significantly less pulmonary insufficiency than a ratio of >1.2 without reducing procedure efficacy.
Предметные рубрики MeSH
Balloon ValvuloplastyBlood PressureCaliforniaCardiac CatheterizationChildChild, PreschoolEchocardiographyFemaleFollow-Up StudiesHumansIncidenceInfantInfant, NewbornMalePostoperative ComplicationsPrognosisPulmonary ValvePulmonary Valve InsufficiencyPulmonary Valve StenosisRetrospective StudiesTime Factors