Cutaneous Adverse Effects From Diabetes Devices in Pediatric Patients With Type 1 Diabetes Mellitus: Systematic Review.

Podwojniak Alicia, Flemming Joseph, Tan Isabella J, Ghani Hira, Neubauer Zachary, Jones Anne

Систематический обзорСтатьяПеревод в очереди

Аннотация

BACKGROUND

Continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusions (CSIIs) are the current standard treatment devices for type 1 diabetes (T1D) management. With a high prevalence of T1D beginning in pediatrics and carrying into adulthood, insufficient glycemic control leads to poor patient outcomes. Dermatologic complications such as contact dermatitis, lipodystrophies, and inflammatory lesions are among those associated with CGM and CSII, which reduce glycemic control and patient compliance.

OBJECTIVE

This systematic review aims to explore the current literature surrounding dermatologic complications of CGM and CSII as well as the impact on patient outcomes.

METHODS

A systematic review of the literature was carried out using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 guidelines using 5 online databases. Included articles were those containing primary data relevant to human participants and adverse reactions to CGM and CSII devices in pediatric populations, of which greater than 50% of the sample size were aged 0-21 years. Qualitative analysis was chosen due to the heterogeneity of outcomes.

RESULTS

Following the application of exclusion criteria, 25 studies were analyzed and discussed. An additional 5 studies were identified after the initial search and inclusion. The most common complication covered is contact dermatitis, with 13 identified studies. Further, 7 studies concerned lipodystrophies, 5 covered nonspecific cutaneous changes, 3 covered unique cutaneous findings such as granulomatous reactions and panniculitis, and 2 discussed user acceptability.

CONCLUSIONS

The dermatologic complications of CGM and CSII pose a potential risk to long-term glycemic control in T1D, especially in young patients where skin lesions can lead to discontinuation. Increased manufacturer transparency is critical and further studies are needed to expand upon the current preventative measures such as device site rotation and steroid creams, which lack consistent effectiveness.

Для цитирования: Podwojniak Alicia, Flemming Joseph, Tan Isabella J, Ghani Hira, Neubauer Zachary, Jones Anne. Cutaneous Adverse Effects From Diabetes Devices in Pediatric Patients With Type 1 Diabetes Mellitus: Systematic Review.. JMIR dermatology. 2024. DOI: 10.2196/59824.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.