m+Medelevator.RU
← Поиск публикаций
Journal of dentistry · 2026

Clinical performance of 3D printed porous titanium dental implants supporting single crowns: A 2-year retrospective study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mangano Carlo, Lerner Henriette, Mangano Francesco Guido

Аннотация

OBJECTIVES: To evaluate the 2-year clinical, radiographic, and prosthetic outcomes of 3D printed porous titanium implants supporting single crowns.

METHODS: This retrospective study included 70 patients (31 males, 39 females; mean age 58.4 ± 12.1 years) rehabilitated with 85 3D printed porous titanium implants supporting single crowns. Forty-six implants (54.1%) were placed in the maxilla and 39 (45.9%) in the mandible; 77 implants (90.6%) were inserted in healed ridges and 8 (9.4%) in post-extraction sockets. Clinical, prosthetic, and radiographic outcomes were assessed after 2 years of functional loading. Outcome measures included implant survival, biologic and prosthetic complications, and marginal bone loss (MBL). Descriptive and inferential statistical analyses were performed with a significance level of p < 0.05.

RESULTS: At the 2-year follow-up, 84 of 85 implants remained functional, resulting in a cumulative survival rate of 98.8%. One implant failed because of peri‑implantitis, while no additional biologic complications were observed. Two prosthetic complications (2.4%) occurred, consisting of implant-abutment connection loss in bruxist patients. Mean MBL increased from 0.65 ± 0.43 mm (95% CI: 0.56-0.74 mm) at 1 year to 0.78 ± 0.50 mm (95% CI: 0.67-0.89 mm) at 2 years, representing a statistically significant change (mean difference: 0.13 mm; 95% CI: 0.07-0.19 mm; p < 0.001). Healed sites exhibited lower MBL than post-extraction sockets, and mandibular implants showed lower MBL than maxillary implants; however, these differences did not reach statistical significance (p > 0.05).

CONCLUSIONS: 3D printed porous titanium implants demonstrated excellent short-term clinical performance, high survival, minimal complication rates, and stable peri‑implant bone levels after 2 years of functional loading, supporting their use for single-tooth implant rehabilitation.

CLINICAL RELEVANCE: 3D printed porous titanium implants may represent a biologically advanced approach to implant design, potentially improving osseointegration through controlled open-cell architecture.

Предметные рубрики MeSH