m+Medelevator.RU
← Поиск публикаций
JACC. Cardiovascular interventions · 2018

Branch Pulmonary Artery Valve Implantation Reduces Pulmonary Regurgitation and Improves Right Ventricular Size/Function in Patients With Large Right Ventricular Outflow Tracts.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Qureshi Athar M, Bansal Neha, McElhinney Doff B, Boudjemline Younes, Forbes Tom J, Maschietto Nicola, Shahanavaz Shabana, Cheatham John P, Krasuski Richard, Lamers Luke, Chessa Massimo, Morray Brian H, Goldstein Bryan H, Noel Cory V, Wang Yunfei, Gillespie Matthew J

Аннотация

OBJECTIVES: The authors sought to assess the intermediate-term effects of percutaneous placed valves in the branch pulmonary artery (PA) position.

BACKGROUND: Most patients with large right ventricular outflow tracts (RVOTs) are excluded from available percutaneous pulmonary valve options. In some of these patients, percutaneous branch PA valve implantation may be feasible. The longer-term effects of valves in the branch PA position is unknown.

METHODS: Retrospective data were collected on patients with significant pulmonary regurgitation who had a percutaneous branch PA valve attempted.

RESULTS: Percutaneous branch PA valve implantation was attempted in 34 patients (18 bilateral and 16 unilateral). One-half of the patients were in New York Heart Association (NHYA) functional class III or IV pre-implantation. There were 2 failed attempts and 6 procedural complications. At follow-up, only 1 patient had more than mild valvar regurgitation. The right ventricular end-diastolic volume index decreased from 147 (range: 103 to 478) ml/m2 to 101 (range: 76 to 429) ml/m2, p < 0.01 (n = 16), and the right ventricular end-systolic volume index decreased from 88.5 (range: 41 to 387) ml/m2 to 55.5 (range: 40.2 to 347) ml/m2, p < 0.01 (n = 13). There were 5 late deaths. At a median follow-up of 2 years, all other patients were in NYHA functional class I or II.

CONCLUSIONS: Percutaneous branch PA valve implantation results in a reduction in right ventricular volume with clinical benefit in the intermediate term. Until percutaneous valve technology for large RVOTs is refined and more widely available, branch PA valve implantation remains an option for select patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты