MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neuroimage.2024.120910

Медицинская библиотека · NeuroImage · 2024

Quantifying neurovascular coupling through a concurrent assessment of arterial, capillary, and neuronal activation in humans: A multimodal EEG-fNIRS-TCD investigation.

Burma Joel S, Oni Ibukunoluwa K, Lapointe Andrew P, Rattana Selina, Schneider Kathryn J, Debert Chantel T, Smirl Jonathan D, Dunn Jeff F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

This study explored a novel multimodal neuroimaging approach to assess neurovascular coupling (NVC) in humans using electroencephalography (EEG), functional near-infrared spectroscopy (fNIRS), and transcranial Doppler ultrasound (TCD).

METHODS

Fifteen participants (nine females; age 19-32) completed concurrent EEG-fNIRS-TCD imaging during motor (finger tapping) and visual ("Where's Waldo?") tasks, with synchronized monitoring of blood pressure, capnography, and heart rate. fNIRS assessed microvascular oxygenation within the frontal, motor, parietal, and occipital cortices, while the middle and posterior cerebral arteries (MCA/PCA) were insonated using TCD. A 16-channel EEG set-up was placed according to the 10-20 system. Wilcoxon signed-rank tests were used to compare physiological responses between the active and resting phases of the tasks, while cross-correlations with zero legs compared cerebral and systemic hemodynamic responses across both tasks.

RESULTS

Time-frequency analysis demonstrated a reduction in alpha and low beta band power in electrodes C3/C4 during finger tapping (p<0.045) and all electrodes during the Waldo task (all p<0.001). During Waldo, cross-correlation analysis demonstrated the change in oxygenated hemoglobin and cerebral blood velocity had a moderate-to-strong negative correlation with systemic physiological influences, highlighting the measured change resulted from neuronal input. Deoxygenated hemoglobin displayed the greatest negative cross-correlation with the MCA/PCA within the motor cortices and visual during the motor and visual tasks, respectively (range:0.54, -0.82).

CONCLUSIONS

This investigation demonstrated the feasibility of the proposed EEG-fNIRS-TCD response to comprehensively assess the NVC response within human, specifically quantifying the real-time temporal synchrony between neuronal activation (EEG), microvascular oxygenation changes (fNIRS), and conduit artery velocity alterations (TCD).

Для цитирования: Burma Joel S, Oni Ibukunoluwa K, Lapointe Andrew P, Rattana Selina, Schneider Kathryn J, Debert Chantel T, Smirl Jonathan D, Dunn Jeff F. Quantifying neurovascular coupling through a concurrent assessment of arterial, capillary, and neuronal activation in humans: A multimodal EEG-fNIRS-TCD investigation.. NeuroImage. 2024. DOI: 10.1016/j.neuroimage.2024.120910.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.