DOI 10.1136/emermed-2020-209700
Technical factors associated with first-pass success during endotracheal intubation in children: analysis of videolaryngoscopy recordings.
Аннотация
BACKGROUND
First-pass success (FPS) during intubation is associated with lower morbidity for paediatric patients. Using videolaryngoscopy (VL) recordings, we reviewed technical aspects of intubation, including factors associated with FPS in children.
METHODS
We performed a retrospective study of intubation attempts performed using video-assisted laryngoscopy in a paediatric ED between January 2014 and December 2018. Data were abstracted from a quality assurance database, the electronic medical record and VL recordings. Our primary outcome was FPS. Intubation practices were analysed using descriptive statistics. Patient and procedural characteristics associated with FPS in univariate testing and clinical factors identified from the literature were included as covariates in a multivariable logistic regression. An exploratory analysis examined the relationship between position of the glottic opening on the video screen and FPS.
RESULTS
Intubation was performed during 237 patient encounters, with 231 using video-assisted laryngoscopy. Data from complete video recordings were available for 129 attempts (59%); an additional 31 (13%) had partial recordings. Overall, 173 (73%) of first attempts were successful. Adjusting for patient age, placing the blade tip into the vallecula adjusted OR ((aOR) 7.2 (95% CI 1.7 to 30.1)) and obtaining a grade 1 or 2a-modified Cormack-Lehane glottic view on the videolaryngoscope screen (aOR 6.1 (95% CI 1.5 to 25.7) relative to grade 2b) were associated with increased FPS in the subset of patients with complete recordings. Exploratory analysis suggested that FPS is highest (81%) and duration is shortest when the glottic opening is located in the second quintile of the video screen.
CONCLUSIONS
Placement of the blade tip into the vallecula regardless of blade type, sufficient glottic visualisation and locating the glottic opening within the second quintile of the video screen were associated with FPS using video-assisted laryngoscopy in the paediatric ED.