MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.cn112138-112138-20231106-00299

Медицинская библиотека · Zhonghua nei ke za zhi · 2024

[Design of an improved percutaneous transhepatic cholangio drainage tube based on MRCP imaging data].

Geng X, Li H L, Hu H T, Guo C Y, Zhang H K, Li J, Yao Q J, Xia W L, Yuan H

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

Objective

Quantified MRCP imaging data was used as a reference for design and preparation of a modified percutaneous transhepatic cholangio drainage (PTCD) tube.

Methods

3.0 T upper abdominal MR and MRCP imaging data of 2 300 patients treated from July 2015 to July 2020 at the Department of Radiology of the Affiliated Cancer Hospital of Zhengzhou University were screened and a total of 381 patients diagnosed with biliary duct structures were identified. Causative etiologies among these patients included pancreatic adenocarcinoma (pancreatic head), cholangiocarcinoma, ampullary carcinoma, as well as intrahepatic and/or extrahepatic bile duct dilation. An improved PTCD tube was designed based on MRCP quantification of left and right hepatic and common hepatic duct length.

Results

In the setting of biliary obstruction caused by malignancy, the distance of the left hepatic duct from its origin to the point of left and right hepatic duct confluence was 15.9±3.8 mm, while the distance of the right hepatic duct from its origin to the point of left and right hepatic duct confluence was 12.4±3.2 mm; the length of the bile duct from its origin to the point of left and right hepatic duct confluence was 34.0±8.1 mm. The improved PTCD tube design incorporated an altered length of the drainage orifice.

Conclusion

MRCP imaging of the biliary tract is effective for measuring biliary tract length in the setting of pathological dilation. Based on our biliary tract measurements, a modified PTCD tube was designed to more effectively meet drainage requirements and manage biliary obstruction caused by Bismuth-Corlette type Ⅱ and Ⅲ malignancies.

Для цитирования: Geng X, Li H L, Hu H T, Guo C Y, Zhang H K, Li J, Yao Q J, Xia W L, Yuan H. [Design of an improved percutaneous transhepatic cholangio drainage tube based on MRCP imaging data].. Zhonghua nei ke za zhi. 2024. DOI: 10.3760/cma.j.cn112138-112138-20231106-00299.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.