MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0194599818806283

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2018

Standardizing Laryngeal Cleft Evaluations: Reliability of the Interarytenoid Assessment Protocol.

Coppess Steven, Padia Reema, Horn David, Parikh Sanjay R, Inglis Andrew, Bly Randall, Dahl John, Dudley Daniel, Johnson Kaalan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

While the Benjamin-Inglis classification system is widely used to categorize laryngeal clefts, it does not clearly differentiate a type 1 cleft from normal anatomy, and there is no widely accepted or validated protocol for systematically evaluating interarytenoid mucosal height. We sought to propose the interarytenoid assessment protocol as a method to standardize the description of the interarytenoid anatomy and to test its reliability.

STUDY

DESIGN

Retrospective review of endoscopic videos.

SETTING

Pediatric academic center.

SUBJECTS AND

METHODS

The interarytenoid assessment protocol comprises 4 steps for evaluation of the interarytenoid region relative to known anatomic landmarks in the supraglottis, glottis, and subglottis. Thirty consecutively selected videos of the protocol were reviewed by 4 otolaryngologists. The raters were blinded to identifying information, and the video order was randomized for each review. We assessed protocol completion times and calculated Cohen's linear-weighted κ coefficient between blinded expert raters and with the operating surgeon to evaluate interrater/intrarater reliability.

RESULTS

Median age was 4.9 years (59 months; range, 1 month to 20 years). Median completion time was 144 seconds. Interrater and intrarater reliability showed substantial agreement (interrater κ = 0.71 [95% confidence interval (CI), 0.55-0.87]; intrarater mean κ = 0.70 [95% CI, 0.59-0.92/rater 1, 0.47-0.85/rater 2]; P < .001). Comparing raters to the operating surgeon demonstrated substantial agreement (mean κ = 0.62; 95% CI, 0.31-0.79/rater 1, 0.48-0.89/rater 2; P < .001).

CONCLUSION

The interarytenoid assessment protocol appears reliable in describing interarytenoid anatomy. Rapid completion times and substantial interrater/intrarater reliability were demonstrated. Incorporation of this protocol may provide important steps toward improved standardization in the anatomic description of the interarytenoid region in pediatric dysphagia.

Для цитирования: Coppess Steven, Padia Reema, Horn David, Parikh Sanjay R, Inglis Andrew, Bly Randall, Dahl John, Dudley Daniel, Johnson Kaalan. Standardizing Laryngeal Cleft Evaluations: Reliability of the Interarytenoid Assessment Protocol.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2018. DOI: 10.1177/0194599818806283.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.