Impact of additional PRV constraint to Direct OAR robust optimization in IMPT for targets near serial organs at risk.

Sundar Sham, Chilukuri Srinivas, Arjunan Manikandan, Selvaraj Rajesh, Guruvaiah Aishwarya, Sharma Dayananda Shamurailatpam

СтатьяПеревод в очереди

Аннотация

PURPOSE: In intensity-modulated proton therapy (IMPT), the benefit of adding planning organ-at-risk volume (PRV)-like nominal constraints to direct robust optimization for serial organs at risk remains uncertain when target-OAR separation is minimal. Using paraspinal chordoma as a model, we evaluated whether an additional nominal canal/thecal sac (PRV-like) constraint improves OAR sparing or compromises target coverage.

METHODS

Ten patients with paraspinal chordomas were planned using two IMPT strategies: direct cord robust optimization alone (Cord-RO) and direct cord optimization with additional nominal canal/thecal sac constraint (Canal-RO). PTV-based helical tomotherapy (HT) was generated as a secondary benchmark. Prespecified institutional criteria were used for planning, prioritizing OAR constraints over coverage; when standard coverage goals were not achieved, GTV D98 ≥ 59 Gy(RBE) was accepted as the fallback criterion. Endpoints included target coverage, cord/canal doses, and robustness. Statistical comparisons used Wilcoxon signed-rank, Friedman, and Cochran's Q tests, two-sided, p < 0.05.

RESULTS

All plans met plan-specific OAR constraints. Cord-RO achieved superior target coverage (median HR-CTV D98 [Gy(RBE)]: 63.05 vs. 57.38 vs. 59.46; p ≤ 0.002) and met the fallback objective (GTV D98 ≥59 Gy[RBE]) in 10/10 cases versus 4/10 and 7/10 (p=0.011) in Canal-RO and HT respectively. Robustness favored Cord-RO (median worst-case CTV D95: 90% vs 85%, p=0.018). Nominal cord D0.03cc was similar; worst-case cord D0.03cc was slightly lower with Canal-RO.

CONCLUSION

When targets abut serial OARs, our results suggest that direct OAR-based robust optimization without additional PRV-like constraints improve target coverage and robustness while maintaining acceptable OAR doses. PRV constraints may be reserved for re-irradiation or when target-OAR separation is adequate.

Для цитирования: Sundar Sham, Chilukuri Srinivas, Arjunan Manikandan, Selvaraj Rajesh, Guruvaiah Aishwarya, Sharma Dayananda Shamurailatpam. Impact of additional PRV constraint to Direct OAR robust optimization in IMPT for targets near serial organs at risk.. Radiation oncology (London, England). 2026. DOI: 10.1186/s13014-026-02866-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.