MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2005.07.027

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2006

Long-term clinical and ultrasound evaluation after arthroscopic acromioplasty in patients with partial rotator cuff tears.

Kartus Jüri, Kartus Catarina, Rostgård-Christensen Lars, Sernert Ninni, Read John, Perko Mark

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Clinical and ultrasound evaluation of patients who had undergone debridement of a partial rotator cuff tear in conjunction with an arthroscopic acromioplasty.

TYPE OF STUDY: Retrospective follow-up study.

METHODS

Thirty-three consecutive patients were included in the study; 26 of the 33 (79%) patients underwent ultrasound evaluation of both shoulders and were examined by independent observers after a follow-up period of 101 months (range, 60 to 128 months; minimum, 5 years).

RESULTS

The median time between onset of symptoms and surgery was 24 months (range, 6 to 360 months). At follow-up, the Constant score was 65 points (range, 15-98). The Constant score on the contralateral side was 84 points (range, 15-96; P < .0001). The strength in abduction was 4.7 kg (range, 1.2 to 11.1 kg) on the operated side and 5.1 kg (range, 1.8 to 10.4 kg) on the contralateral side (not significant). Twelve of the 26 patients reported discomfort or pain in the contralateral shoulder and during the follow-up period, and 3 of 26 had undergone an arthroscopic acromioplasty of the contralateral shoulder. Two of 26 patients underwent further surgery of the index shoulder during the follow-up period. The visual analogue score for pain for the index shoulder was 20 mm (range, 0 to 85). The ultrasound evaluation revealed that 9 of 26 patients had a full-thickness rotator cuff tear in the index shoulder and, of these, 3 of 9 were bilateral.

CONCLUSIONS

It appears that an arthroscopic acromioplasty and rotator cuff debridement in patients with partial tears does not protect the rotator cuff from undergoing further degeneration.

LEVEL OF EVIDENCE: Level IV.

Для цитирования: Kartus Jüri, Kartus Catarina, Rostgård-Christensen Lars, Sernert Ninni, Read John, Perko Mark. Long-term clinical and ultrasound evaluation after arthroscopic acromioplasty in patients with partial rotator cuff tears.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2006. DOI: 10.1016/j.arthro.2005.07.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.