Clinical oncology (Royal College of Radiologists (Great Britain)) · 2019
Dosimetry and Gastrointestinal Toxicity Relationships in a Phase II Trial of Pelvic Lymph Node Radiotherapy in Advanced Localised Prostate Cancer.
Клиническое исследование II фазыСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ferreira M R, Thomas K, Truelove L, Khan A, Parker C, Dearnaley D P, Gulliford S
Аннотация
AIMS: Pelvic lymph node (PLN) radiotherapy for high-risk prostate cancer is limited by late gastrointestinal toxicity. Application of rectal and bowel constraints may reduce risks of side-effects. We evaluated associations between intensity-modulated radiotherapy (IMRT) dose-volume data and long-term gastrointestinal toxicity.
MATERIALS AND METHODS: Data from a single-centre dose-escalation trial of PLN-IMRT were analysed, including conventionally fractionated (CFRT) and hypofractionated (HFRT) radiotherapy schedules. Associations between volumes of rectum and bowel receiving specified doses and clinician- and patient-reported toxicity outcomes were investigated independently. A metric, δ median (δM), was defined as the difference in the medians of a volume between groups with and without toxicity at a specified dose and was used to test for statistically significant differences.
RESULTS: Constraints were respected in most patients and, when exceeded, led to higher rates of gastrointestinal toxicity. Biologically relevant associations between rectum dose-points and toxicity were more numerous with both mild and moderate toxicity thresholds, but statistical significance was limited after correction for false discovery rate. Rectal V50Gy (CFRT) associated with grade 2+ bleeding; bowel V43Gy and V47 (HFRT/4 days/week schedule) associated with patient-reported loose stools and diarrhoea, respectively. Further investigation showed that CFRT patients with rectal bleeding had a mean rectal V50Gy above the treatment planning constraint.
CONCLUSIONS: When dose-volume parameters are kept below tight constraints, toxicity is low. Residual dosimetry loses much of its predictive power for gastrointestinal toxicity in the setting of PLN-IMRT for prostate cancer. We have benchmarked dose-volume constraints for safely delivering PLN-IMRT using CFRT or HFRT.
MATERIALS AND METHODS: Data from a single-centre dose-escalation trial of PLN-IMRT were analysed, including conventionally fractionated (CFRT) and hypofractionated (HFRT) radiotherapy schedules. Associations between volumes of rectum and bowel receiving specified doses and clinician- and patient-reported toxicity outcomes were investigated independently. A metric, δ median (δM), was defined as the difference in the medians of a volume between groups with and without toxicity at a specified dose and was used to test for statistically significant differences.
RESULTS: Constraints were respected in most patients and, when exceeded, led to higher rates of gastrointestinal toxicity. Biologically relevant associations between rectum dose-points and toxicity were more numerous with both mild and moderate toxicity thresholds, but statistical significance was limited after correction for false discovery rate. Rectal V50Gy (CFRT) associated with grade 2+ bleeding; bowel V43Gy and V47 (HFRT/4 days/week schedule) associated with patient-reported loose stools and diarrhoea, respectively. Further investigation showed that CFRT patients with rectal bleeding had a mean rectal V50Gy above the treatment planning constraint.
CONCLUSIONS: When dose-volume parameters are kept below tight constraints, toxicity is low. Residual dosimetry loses much of its predictive power for gastrointestinal toxicity in the setting of PLN-IMRT for prostate cancer. We have benchmarked dose-volume constraints for safely delivering PLN-IMRT using CFRT or HFRT.