Biomechanical analysis in hip joints according to sagittal pelvic tilt in non-ambulatory flaccid neuromuscular scoliosis: a finite element study.

Shin Jae Won, Kim Dong Ki, Kim Sang Ho, Suk Kyung Soo, Moon Seong Hwan, Park Si Young, Lee Byung Ho, Kwon Ji Won, Lee Sung Jae, Kim Hak Sun

СтатьяПеревод в очереди

Аннотация

PURPOSE: To quantify the biomechanical effect of postoperative sagittal pelvic tilt (SA-PT) on hip joint stress and to relate the simulation findings to clinically observed hip migration and pain in non-ambulatory patients with flaccid neuromuscular (NM) scoliosis.

METHODS

Three representative postoperative CT scans (SA-PT + 30°, 0°, -15°) were segmented and mirrored to create symmetric pelvis-femur models. Cartilage was modeled as a 1.0 mm isotropic elastic layer. Five SA-PT angles (-30° to + 30°) were simulated by rotating the pelvis around the bicoxofemoral axis. A 400 N compressive load was applied vertically to S1; the distal posterior femur was fixed to simulate seating. Frictionless cartilage-cartilage contact was used. Mesh convergence was confirmed (< 5% PVMS change), and peak von Mises stress (PVMS) and contact force vectors were extracted. Correlations between ΔPVMS and clinical changes in Reimers migration percentage (RMP) and pain VAS were analyzed using Spearman tests; multivariable regression assessed predictors of PVMS.

RESULTS

Mean right hip PVMS decreased with increasing SA PT: -30° 22.4 MPa, -15° 21.6 MPa, 0° 18.1 MPa, + 15° 16.8 MPa, + 30° 9.4 MPa. PVMS at -15° was 38% higher than at + 15°. Stress shifted from central (SA-PT + 30°) to superomedial (-30°). ΔPVMS correlated with ΔRMP (ρ = 0.46, p < 0.001) and ΔVAS (ρ = 0.41, p = 0.002). SA-PT was an independent PVMS predictor (β = -0.37 MPa/5°, p < 0.001).

CONCLUSIONS

Postoperative reduction in SA-PT increases acetabular cartilage stress and produces an unfavorable superomedial load shift that mirrors the clinically observed rise in hip migration and pain.

Другие публикации по теме

ScoliosisHip JointBiomechanical PhenomenaFinite Element Analysis
Для цитирования: Shin Jae Won, Kim Dong Ki, Kim Sang Ho, Suk Kyung Soo, Moon Seong Hwan, Park Si Young, Lee Byung Ho, Kwon Ji Won, Lee Sung Jae, Kim Hak Sun. Biomechanical analysis in hip joints according to sagittal pelvic tilt in non-ambulatory flaccid neuromuscular scoliosis: a finite element study.. Spine deformity. 2026. DOI: 10.1007/s43390-025-01230-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.