MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02841851241253775

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2024

Utility of combining multiple parameters of 123I-IMP SPECT and voxel-based morphometry MRI using a multiparametric scoring system for differentiating dementia with Lewy bodies from Alzheimer's disease.

Matsusue Eiji, Inoue Chie, Shimoda Manabu, Nakamura Tomoya, Matsumoto Shota, Matsumoto Kensuke, Tanino Tomohiko, Nakamura Kazuhiko, Fujii Shinya

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Brain magnetic resonance imaging voxel-based morphometry (VBM) and perfusion single-photon emission computed tomography (SPECT) are useful for differentiating dementia with Lewy bodies (DLB) from Alzheimer's disease (AD).

PURPOSE: To determine whether combining multiple parameters of VBM and SPECT using a multiparametric scoring system (MSS) improves diagnostic accuracy in differentiating DLB from AD.

MATERIAL AND

METHODS

In total, 23 patients with DLB and 57 patients with AD underwent imaging using a voxel-based specific regional analysis system for AD (VSRAD), an easy Z-score imaging system, and a Z-Graph using three-dimensional stereotactic surface projection. The cutoff values were determined using the receiver operating characteristic curve to differentiate DLB from AD for all parameters. Patients were scored 1 (DLB) or 0 (AD) for each statistically significant parameter, according to a threshold. The total score was determined for each case to obtain a cutoff value for the MSS.

RESULTS

The mean Z-scores in the medial temporal lobes using the VSRAD were significantly lower in patients with DLB than in those with AD. Each Z-score of the summed Z-scores in all four segmented regions of the occipital lobes using the Z-Graph was significantly higher in patients with DLB than in those with AD. Among the five parameters, the highest accuracy was 80% for the Z-score of the summed Z-scores in the left medial occipital lobe. For the MSS, a cutoff value of four improved the diagnostic accuracy to 82%.

CONCLUSION

MSS was more accurate than any single parameter of VBM or SPECT in differentiating DLB from AD.

Для цитирования: Matsusue Eiji, Inoue Chie, Shimoda Manabu, Nakamura Tomoya, Matsumoto Shota, Matsumoto Kensuke, Tanino Tomohiko, Nakamura Kazuhiko, Fujii Shinya. Utility of combining multiple parameters of 123I-IMP SPECT and voxel-based morphometry MRI using a multiparametric scoring system for differentiating dementia with Lewy bodies from Alzheimer's disease.. Acta radiologica (Stockholm, Sweden : 1987). 2024. DOI: 10.1177/02841851241253775.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.