MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ejn.15531

Медицинская библиотека · The European journal of neuroscience · 2021

Correcting whole-body motion capture data using rigid body transformation.

Miyakoshi Makoto

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Using motion capture data as a part of mobile brain-body imaging (MoBI) recording has been increasing. With minimal linear algebra background, this paper explains how the rigid body transformation can be a useful preprocessing step for denoising and missing marker recovery. Such a transformation can provide insight and necessary-and-sufficient solutions requiring no assumption other than the minimum number of markers present. First, a simulation test using the empirical datasets from the AudioMaze project published from this journal's same volume demonstrates theoretical accuracy. The simulation results show that the rigid-body method perfectly recovers missing markers on a rigid body if a minimum of three marker positions is available. Second, the same transformation is applied to the empirical dataset. Before preprocessing, the raw data show that 15-80% of data frames had all markers present for rigid-body defined body parts. After using the rigid-body correction, most body parts recovered full markers in 90-95% of the data frames. The result also suggests the necessity for performing across-trial corrections for within-participant (42% missing detected in one of the body parts) and across-participants (11% missing). The discussion section introduces a solution and a performance summary for non-rigid-body marker correction using a neural network. Data support that the rigid body transformation is an intuitive and powerful correction method necessary for preprocessing motion capture data for neurocognitive experiments. The supporting information section contains a URL link to Matlab code and example data.

Для цитирования: Miyakoshi Makoto. Correcting whole-body motion capture data using rigid body transformation.. The European journal of neuroscience. 2021. DOI: 10.1111/ejn.15531.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.