MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10877-023-01084-4

Медицинская библиотека · Journal of clinical monitoring and computing · 2023

Use of near infrared spectroscopy for the prediction of perioperative complications in patients undergoing elective microsurgical resection of cerebral arteriovenous malformations- a prospective observational trial (NIRSCAM trial).

Thomas Jithumol Thankam, Hrishi P Ajay Prasad, Praveen Ranganatha, Sethuraman Manikandan, Prathapadas Unnikrishnan, Vimala Smita, Mathew Oommen

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: Cerebral arteriovenous malformations (AVM) represent focal abnormal areas of low resistance circulation which render the peri-nidal neuronal tissue susceptible to ischemia. The post-excision cerebral perfusion surge can result in hyperaemic complications.We hypothesised that Near Infrared Spectroscopy (NIRS)-guided perioperative management can aid in the prediction and prevention of perioperative complications in patients presenting for surgical excision of cerebral AVMs. We also intended to identify a threshold value of regional cerebral oxygen saturation (rScO2) to predict the incidence of perioperative complications.

METHODS

This was a prospective observational study involving patients undergoing elective supratentorial AVM resection surgeries. Intraoperative rScO2 and hemodynamic monitoring were done and continued for postoperatively for 12 h. Any drift in rScO2 by > 12% from baseline was managed as per study protocol and perioperative adverse events were recorded and analyzed. Post surgery,for analytical purpose patients were categorized into two groups, Group A - patients without complications and Group B - patients who had complications postoperatively.

RESULTS

Twenty-five patients presenting for surgical excision of cerebral AVM were recruited for this study of which 9 patients had postoperative adverse events and were allocated to group B. The ipsilateral mean rScO2 at the time of complication (Pc) was significantly lower in Group B than in group A [62.08 ± 9.33 vs.70.52 ± 7.17; p = 0.04]. The mean ipsilateral rScO2 drift from N2- N5 (i.e., post excision) was significantly higher in Group B than in Group A [12.01 ± 2.63% vs. 4.98 ± 5.7%;p = 0.02]. Mean ipsilateral rScO2 Drift ratio (N5 :N2) was significantly higher in group B as compared to group A [1.32 ± 0.01 vs. 1.01 ± 0.06;p < 0.001]. In the immediate post excision phase, the ipsilateral mean rScO2 was significantly higher in Group B at the post excision time point compared to Group A [ 83.03 ± 6.08 vs. 73.52 ± 7.07;p < 0.01)]. The mean ipsilateral rScO2 drift from N1-N6 (i.e., postoperatively) was significantly higher in Group B as compared to Group A [14.96 ± 0.080% vs. 6.88 ± 4.5% ; p < 0.01]. Similarly, the Mean Ipsilateral rScO2 Drift ratio (N6:N1) was significantly lower in group B as compared to group A [2.17 ± 0.02 vs. 1.05 ± 0.03 ;p < 0.0001].

CONCLUSIONS

In patients undergoing cerebral AVM resection, a post-resection ipsilateral rScO2 increase by > 12% with a drift ratio of > 1.3 could signify cerebral hyperemia. A postoperative ipsilateral rScO2 drift > 14.5% with a drift ratio of 2.1 from the baseline is associated with postoperative complications in our study. Further multi-centric randomized control trials are needed to support our research findings.

Для цитирования: Thomas Jithumol Thankam, Hrishi P Ajay Prasad, Praveen Ranganatha, Sethuraman Manikandan, Prathapadas Unnikrishnan, Vimala Smita, Mathew Oommen. Use of near infrared spectroscopy for the prediction of perioperative complications in patients undergoing elective microsurgical resection of cerebral arteriovenous malformations- a prospective observational trial (NIRSCAM trial).. Journal of clinical monitoring and computing. 2023. DOI: 10.1007/s10877-023-01084-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.