High serum matrix metalloproteinase-3 and liver stiffness in postoperative biliary atresia.
Аннотация
BACKGROUND
Biliary atresia (BA) is a neonatal liver disorder characterized by chronic inflammation and obliteration of extrahepatic bile ducts. The purpose of the study was to investigate serum matrix metalloproteinase-3 (MMP-3) in postoperative BA patients and the association of MMP-3 with clinical outcome and liver stiffness score.
METHODS
Fifty-eight BA patients post-Kasai operation and 20 controls were enrolled. None of the patients had undergone liver transplantation. BA patients were classified into two groups according to their serum total bilirubin (TB) levels (TB < 2 mg/dL, no jaundice vs. TB ≥ 2 mg/dL, persistent jaundice) and alanine aminotransferase (ALT) levels (ALT < 45 IU/L, normal ALT vs. ALT ≥ 45 IU/L, elevated ALT). Serum MMP-3 levels were determined by enzyme-linked immunosorbent assay. Liver stiffness scores were measured by FibroScan.
RESULTS
BA patients had greater MMP-3 levels (10.8 ± 1.0 vs. 7.9 ± 0.8 ng/mL, P = 0.02) and higher liver stiffness values than controls (29.7 ± 3.0 vs. 5.1 ± 0.5 kPa, P < 0.001). Serum MMP-3 levels were significantly elevated in BA patients with jaundice when compared with those without jaundice (15.3 ± 2.2 vs. 8.5 ± 0.8 ng/mL, P = 0.004). In addition, BA patients with elevated ALT had higher levels of serum MMP-3 than those with normal ALT (12.4 ± 1.5 vs. 8.3 ± 0.9 ng/mL, P = 0.02). Moreover, BA patients with portal hypertension displayed higher serum MMP-3 than those without portal hypertension (13.5 ± 1.5 vs. 7.4 ± 0.8 ng/mL, P = 0.001). There was also a correlation between serum MMP-3 and liver stiffness scores (r = 0.448, P ≤ 0.001).
CONCLUSION
Serum MMP-3 was associated with hepatic dysfunction and liver stiffness in postoperative BA patients. Accordingly, MMP-3 could play a role in the pathophysiology of hepatic fibrosis in BA after Kasai operation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.