m+Medelevator.RU
← Поиск публикаций
Regulatory toxicology and pharmacology : RTP · 2016

Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ahn Ilyoung, Kim Tae-Sung, Jung Eun-Sun, Yi Jung-Sun, Jang Won-Hee, Jung Kyoung-Mi, Park Miyoung, Jung Mi-Sook, Jeon Eun-Young, Yeo Kyeong-Uk, Jo Ji-Hoon, Park Jung-Eun, Kim Chang-Yul, Park Yeong-Chul, Seong Won-Keun, Lee Ai-Young, Chun Young Jin, Jeong Tae Cheon, Jeung Eui Bae, Lim Kyung-Min, Bae SeungJin, Sohn Soojung, Heo Yong

Аннотация

Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты