MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000004437

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2025

Cochlear Implantation in Vestibular Schwannoma Surgery: Diagnostic Accuracy Analysis of Intraoperative Monitoring with Intracochlear Electrode.

Zanoletti Elisabetta, Concheri Stefano, Tealdo Giulia, Cazzador Diego, Di Pasquale Fiasca Valerio M, Franchella Sebastiano, Impala' Giuseppe, Brotto Davide

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the role of intraoperative cochlear nerve (CN) electric monitoring with MED-EL intracochlear test electrode (ITE) in assessing the CN functional integrity.

SETTING

Tertiary referral center.

PATIENTS: Patients with intrameatal or 2 to 13 mm in the cerebello-pontine angle vestibular schwannoma (VS), not suitable for hearing preservation surgery but eligible for tumor resection via translabyrinthine approach and simultaneous cochlear implant (CI) rehabilitation.

INTERVENTION: ITE was used to register electrically evoked auditory brainstem response (eABR) before and after VS resection. All patients with anatomical preservation of CN underwent CI, regardless of eABR results, which served as the index test and was compared with postoperative sound perception by CI stimuli (gold standard test).

RESULTS

Twelve of seventeen cases allowed anatomical preservation of CN and were considered for the study. Seven of twelve cases demonstrated sound detection with CI, and six of twelve showed some degree of speech discrimination. eABR test with ITE achieved an accuracy of 66.7%, a sensitivity of 42.9%, and a specificity of 100%. Positive and negative predictive values were 100% and 55.6%, respectively.

CONCLUSION

When eABR can be evoked with ITE, the attempt of CI was likely to be successful, whereas in cases of eABR absence, other factors should be considered to reduce unsuccessful CI and not preclude rehabilitation in patients who would benefit from CI. Further studies and longer follow-up are needed to analyze the role of ITE in VS surgery with CI.

Для цитирования: Zanoletti Elisabetta, Concheri Stefano, Tealdo Giulia, Cazzador Diego, Di Pasquale Fiasca Valerio M, Franchella Sebastiano, Impala' Giuseppe, Brotto Davide. Cochlear Implantation in Vestibular Schwannoma Surgery: Diagnostic Accuracy Analysis of Intraoperative Monitoring with Intracochlear Electrode.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2025. DOI: 10.1097/mao.0000000000004437.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.