MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jsap.12486

Медицинская библиотека · The Journal of small animal practice · 2016

Short-term outcome and complications of TPLO using anatomically contoured locking compression plates in small/medium-breed dogs with "excessive" tibial plateau angle.

Barnes D C, Trinterud T, Owen M R, Bush M A

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To report short-term radiographic and clinical outcome and complications following tibial plateau levelling osteotomy for the treatment of cranial cruciate ligament insufficiency in dogs less than 18·1 kg with tibial plateau angle greater than 35° using anatomically contoured six-hole locking compression plates.

METHODS

Retrospective data were collected on: preoperative, postoperative and follow-up tibial plateau angles, plateau segment rotation, tibial tuberosity width and length of the cranial aspect of tibial tuberosity segment from the patellar tendon insertion and rotation of the tibial plateau below the level of the insertion of the patellar ligament.

RESULTS

In 26 small dogs (29 stifles in total), mean preoperative, postoperative and follow-up tibial plateau angles were 38·2°, 4·8°, and 4·4°, respectively. Documented postoperative complications were limited to patellar tendinopathy in a single case (3·4%) and tibial tuberosity or fibula fracture were not observed.

CLINICAL SIGNIFICANCE: Short-term radiographic and clinical outcome of tibial plateau levelling osteotomy stabilised with anatomically contoured six-hole locking compression plates for the treatment of small dogs with large tibial plateau angle suggests a very low risk of complications. Rotation beyond the "safe point" is necessary to perform full rotation in some cases, but does not appear to incur an increased risk of tibial tuberosity fracture.

Для цитирования: Barnes D C, Trinterud T, Owen M R, Bush M A. Short-term outcome and complications of TPLO using anatomically contoured locking compression plates in small/medium-breed dogs with "excessive" tibial plateau angle.. The Journal of small animal practice. 2016. DOI: 10.1111/jsap.12486.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.