MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000001259

Медицинская библиотека · Eye & contact lens · 2026

Change in Corneo-Scleral Thickness of Myopic Children Wearing Overnight Orthokeratology: 6 Months Follow-Up Study.

Guo Yin, Sun Xiaojun, Wang Xinchao, Guan Chunlei, Tian Mengchen, Cui Min, Liu Xin, Yuan Jiahong, Zhang Qi, Yan Lijuan, Ren Xuetao, Yu Xiuting, Meng Bin, Ji Ang

СтатьяПеревод в очереди

Аннотация

PURPOSE: To explore changes in corneoscleral thickness among myopic children undergoing overnight orthokeratology (Ortho-k) and assess potential associations with axial elongation.

METHODS

This prospective study included myopic children receiving Ortho-k lens treatment with regular follow-ups in 6 months. Corneo-scleral cross-sectional images were obtained using a SPECTRALIS optical coherence tomography device. Measurements of anterior scleral thickness were taken at nasal (SS-N), temporal scleral spur (SS-T), and 1 mm away from these locations (SS-N1 and SS-T1).

RESULTS

A total of 24 children (38 eyes) with a mean age of 10.3±2.2 years were included. The mean thickness was 643±48.0 μm at SS-T, 611±50.7 μm at SS-N, 515±44.6 μm at SS-T1, and 506±37.5 μm at SS-N1. Boys exhibited significantly greater scleral thickness at SS-N1 and SS-T1 compared with girls ( P =0.01). After 6 months of Ortho-k use, significant thinning was observed at SS-T (from 643±48.0 μm to 616±44.0 μm; P =0.001) and SS-N (from 611±50.7 μm to 593±54.8 μm; P =0.015) compared with baseline values. However, the scleral thickness at 1 mm from the SS remained stable. No significant correlation was found between axial elongation and scleral thickness. A subgroup of monocular Ortho-k wearers found that SS-T and SS-N values decreased in eyes with monocular lens-wearing but remained stable in the untreated eyes.

CONCLUSIONS

A significant reduction in corneo-scleral thickness was observed after six months of Ortho-k lens wear. These changes warrant further investigation to confirm their implications and underlying mechanisms.

Для цитирования: Guo Yin, Sun Xiaojun, Wang Xinchao, Guan Chunlei, Tian Mengchen, Cui Min, Liu Xin, Yuan Jiahong, Zhang Qi, Yan Lijuan, Ren Xuetao, Yu Xiuting, Meng Bin, Ji Ang. Change in Corneo-Scleral Thickness of Myopic Children Wearing Overnight Orthokeratology: 6 Months Follow-Up Study.. Eye & contact lens. 2026. DOI: 10.1097/icl.0000000000001259.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.