MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1182/blood-2012-07-444042

Медицинская библиотека · Blood · 2012

Deep-sequencing approach for minimal residual disease detection in acute lymphoblastic leukemia.

Faham Malek, Zheng Jianbiao, Moorhead Martin, Carlton Victoria E H, Stow Patricia, Coustan-Smith Elaine, Pui Ching-Hon, Campana Dario

Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The persistence of minimal residual disease (MRD) during therapy is the strongest adverse prognostic factor in acute lymphoblastic leukemia (ALL). We developed a high-throughput sequencing method that universally amplifies antigen-receptor gene segments and identifies all clonal gene rearrangements (ie, leukemia-specific sequences) at diagnosis, allowing monitoring of disease progression and clonal evolution during therapy. In the present study, the assay specifically detected 1 leukemic cell among greater than 1 million leukocytes in spike-in experiments. We compared this method with the gold-standard MRD assays multiparameter flow cytometry and allele-specific oligonucleotide polymerase chain reaction (ASO-PCR) using diagnostic and follow-up samples from 106 patients with ALL. Sequencing detected MRD in all 28 samples shown to be positive by flow cytometry and in 35 of the 36 shown to be positive by ASO-PCR and revealed MRD in 10 and 3 additional samples that were negative by flow cytometry and ASO-PCR, respectively. We conclude that this new method allows monitoring of treatment response in ALL and other lymphoid malignancies with great sensitivity and precision. The www.clinicaltrials.gov identifier number for the Total XV study is NCT00137111.

Для цитирования: Faham Malek, Zheng Jianbiao, Moorhead Martin, Carlton Victoria E H, Stow Patricia, Coustan-Smith Elaine, Pui Ching-Hon, Campana Dario. Deep-sequencing approach for minimal residual disease detection in acute lymphoblastic leukemia.. Blood. 2012. DOI: 10.1182/blood-2012-07-444042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.