MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.70231

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2026

Multisequence MRI Enables High-Fidelity FDG-PET Synthesis for Epilepsy Using GANs.

Yao Chenyang, Cui Bixiao, Wang Jingjuan, Wang Zhen-Ming, Wu Chunxue, Shan Yi, Yang Hongwei, Lu Jie

СтатьяПеревод в очереди

Аннотация

BACKGROUND

FDG-PET aids presurgical epilepsy evaluation but is limited by access and radiation exposure.

PURPOSE: To evaluate synthetic FDG-PET generated from T1-weighted imaging and resting-state fMRI metrics.

STUDY TYPE: Retrospective.

POPULATION: 481 participants underwent simultaneous FDG PET/MR. Internal cohort: 311 epilepsy patients split into training/validation/internal test sets (n = 249/31/31; age 18.79 ± 16.33/22.20 ± 11.21/21.65 ± 17.62 years; male/female 145/104, 13/18, 22/9). External cohort: 115 temporal lobe epilepsy patients (age 25.36 ± 10.95 years; male/female 68/47) and 55 healthy controls (age 27.62 ± 5.82 years; male/female 24/31); 92 had surgery with 1-year outcome.

FIELD STRENGTH: Hybrid PET/MR at 3.0 T; gradient-echo T1WI, echo-planar imaging and resting-state BOLD gradient-echo EPI.

ASSESSMENT: Performance was assessed using SSIM, PSNR, MSE, NRMSE, SUVR correlation, and Bland-Altman analysis. Three blinded readers performed visual quality grading and detection of temporal lobe hypometabolism. Hippocampal radiomics was used for classification of hippocampal sclerosis and Engel outcome.

STATISTICAL TESTS: t-tests, chi-square tests, Pearson correlation, Kolmogorov-Smirnov tests, DeLong tests, and false discovery rate correction.

RESULTS

Excellent/Good visual ratings occurred in 82.8% (166/201), with Fleiss' κ = 0.42. SSIM was 0.98 ± 0.01 (internal) and 0.97 ± 0.01 (external); PSNR was 66.66 ± 1.25 and 64.16 ± 1.83, respectively. SUVR correlation with ground-truth PET was r = 0.94 (internal) and r = 0.89 (external); Bland-Altman bias was -0.02 (95% limits of agreement: -0.22 to 0.18) internally and -0.00002 (95% limits: -0.35 to 0.35) externally. Detection accuracy for temporal hypometabolism was 90.3% (internal; κ = 0.735) and 87.1% (external; κ = 0.758). Radiomics AUCs using synthetic PET were 0.72 (95% CI: 0.62-0.83) for hippocampal sclerosis versus healthy controls and 0.77 (95% CI: 0.67-0.87) for Engel IA versus IB-IV; DeLong tests versus ground-truth PET were non-significant (p = 0.56 and p = 0.48).

CONCLUSION

Multisequence MRI-based synthetic PET showed high agreement with ground-truth PET across image-quality and quantitative SUVR metrics, providing a PET-like metabolic surrogate when FDG-PET is unavailable or impractical.

LEVEL OF EVIDENCE: Evidence Level 3.

STAGES OF TECHNICAL EFFICACY: Stage 3.

Для цитирования: Yao Chenyang, Cui Bixiao, Wang Jingjuan, Wang Zhen-Ming, Wu Chunxue, Shan Yi, Yang Hongwei, Lu Jie. Multisequence MRI Enables High-Fidelity FDG-PET Synthesis for Epilepsy Using GANs.. Journal of magnetic resonance imaging : JMRI. 2026. DOI: 10.1002/jmri.70231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.