Successful detection of postoperative improvement of dynamic sagittal balance with a newly developed three-dimensional gait motion analysis system in a patient with iatrogenic flatback syndrome: A case report.

Miura Kousei, Koda Masao, Kadone Hideki, Abe Tetsuya, Kumagai Hiroshi, Nagashima Katsuya, Mataki Kentaro, Fujii Kengo, Noguchi Hiroshi, Funayama Toru, Suzuki Kenji, Yamazaki Masashi

Клинический случайСтатьяПеревод в очереди

Аннотация

A 75-year-old Japanese woman with Parkinson's disease complained of lower back pain and gait disturbance because of iatrogenic flatback syndrome. The preoperative global spinal parameters were as follows: C7SVA, 168 mm; TK, 52°; LL, -0.8°; PI, 57°; PT, 55°; TPA, 60°. We performed 3D gait analysis using a VICON System and calculated the dynamic SVA. Preoperatively, her flexion deformity gradually progressed during walking. The dynamic parameters gradually increased as follows: thoracic SVA, 216-241 mm; lumbar SVA, 53-69 mm; spinal SVA, 270-311 mm. We performed two-stage corrective surgery. Her lower back pain and gait disturbance significantly improved. The postoperative global spinal parameters were as follows: C7SVA, 1 mm; TK, 47°; LL, 61°; PI, 52°; PT, 20°; TPA, 13°. Dynamic SVA detected by our 3D gait analysis using VICON were as follows: thoracic SVA, 128 mm; lumbar SVA, 4.9 mm; and spinal SVA, 133 mm. The postoperative dynamic SVA did not change during walking. This is the first report of a patient with iatrogenic flatback syndrome whose postoperative improvement of dynamic spinal sagittal alignment was successfully detected with a newly developed 3D gait analysis system that enabled us to analyze a dynamic change of SVA based on the patient's actual walking with a continuous long-distance gait. Our 3D gait analysis has potential usefulness for evaluating postoperative sagittal balance for iatrogenic flatback syndrome.

Для цитирования: Miura Kousei, Koda Masao, Kadone Hideki, Abe Tetsuya, Kumagai Hiroshi, Nagashima Katsuya, Mataki Kentaro, Fujii Kengo, Noguchi Hiroshi, Funayama Toru, Suzuki Kenji, Yamazaki Masashi. Successful detection of postoperative improvement of dynamic sagittal balance with a newly developed three-dimensional gait motion analysis system in a patient with iatrogenic flatback syndrome: A case report.. Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia. 2018. DOI: 10.1016/j.jocn.2018.04.051.