PURPOSE: The etiology of spontaneous extensor pollicis longus (EPL) tendon rupture is still largely unknown. It is possible that friction within the sheath may play a role. The purposes of this study were to compare gliding resistance of the EPL tendon with that of the extensor digitorum communis tendon of the index finger (EDC II) and to find the wrist position that gives the EPL tendon the lowest gliding resistance.

METHODS

Fifteen fresh-frozen cadavers were used. Gliding resistance was measured directly in 7 different wrist positions.

RESULTS

The mean gliding resistance of the EPL tendon was 0.16 +/- 0.08 N and that of the EDC II tendon was 0.11 +/- 0.06 N. This difference was significant. There was also a significant effect on gliding resistance due to wrist position. For the EPL tendon, the gliding resistance was significantly greater in 60 degrees wrist flexion compared with all other wrist positions tested. Additionally the gliding resistance of the EPL in 30 degrees flexion, 60 degrees extension, and 15 degrees radial deviation was significantly higher than wrist positions of 30 degrees extension, neutral, and 30 degrees ulnar deviation.

CONCLUSIONS

Positioning the wrist close to neutral flexion/extension and in some ulnar deviation minimizes the friction within the EPL sheath. Such positions may be advantageous for splinting patients at risk for EPL rupture.

Для цитирования: Kutsumi Keiji, Amadio Peter C, Zhao Chunfeng, Zobitz Mark E, An Kai-Nan. Measurement of gliding resistance of the extensor pollicis longus and extensor digitorum communis II tendons within the extensor retinaculum.. The Journal of hand surgery. 2004. DOI: 10.1016/j.jhsa.2003.10.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.