m+Medelevator.RU
← Поиск публикаций
Acta orthopaedica et traumatologica turcica · 2026

Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yurteri Ahmet, Mercan Numan, Kekeç Ahmet Fevzi, Tahak Fatih, Yıldırım Ahmet

Аннотация

OBJECTIVE: To evaluate the clinical and radiographic outcomes of tibiotalocalcaneal (TTC) arthrodesis performed using a lateral transfibular approach with the off-label application of a Proximal Humerus Internal Locking System (PHILOS) plate and to exploratorily assess outcomes according to the use of supplemental medial cannulated screw fixation.

METHODS: Thirty patients (32 ankles) who underwent TTC arthrodesis between January 2019 and June 2024 and had ≥12 months of followup were retrospectively reviewed. Demographics, comorbidities, surgical indications, implant configuration, fusion rates, complications, reoperations, and patient satisfaction were analyzed. Subgroup findings regarding medial screw support were evaluated descriptively.

RESULTS: The mean follow-up duration was 37.3 ± 19.2 months, and fusion was achieved in 90.6% (29/32) of ankles. Complications occurred in 18.8% (6/32), including 3 nonunions, 2 peri-implant tibial fractures, and 1 superficial infection. Reoperation was required in 3 ankles (9.4%). Patient-reported satisfaction was "excellent" in 71.9%, "good" in 12.5%, "fair" in 6.3%, and "poor" in 9.4%.

CONCLUSION: Tibiotalocalcaneal arthrodesis performed using the PHILOS plate with a lateral approach demonstrated acceptable fusion and complication rates in this cohort. Subgroup observations regarding supplemental medial screw fixation should be interpreted as exploratory and hypothesis generating.   Cite this article as: Yurteri A, Mercan N, Kekeç AF, Tahak F, Yıldırım A. Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles. Acta Orthop Traumatol Turc.2026; 60(4), 0553, doi: 10.5152/j.aott.2026.25553.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты