DOI 10.1177/02841851241271999

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2024

Comparison of different radiographic methods to measure the slip angle in children with slipped capital femoral epiphysis (SCFE).

Lindell Mikael, Nilsson Jens, Herngren Bengt, Örtegren Jakob, Stenmarker Margaretha, Tiderius Carl Johan, Michno Piotr

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The management of patients with slipped capital femoral epiphysis (SCFE) requires imaging diagnostics of good quality and accurate measurement of the degree of slippage. In Sweden, three different radiological methods are commonly used: the calcar femorale method; the Billing method; and the Head-shaft angle described by Southwick.

PURPOSE: To evaluate whether any of the three most common methods used in Sweden to measure the slip angle was more useful and reproducible than the others.

MATERIAL AND

METHODS

Two experienced orthopaedists measured the slip angle in preoperative hip radiographs. Intra- and inter-observer variability between the two experienced observers and the reported value by clinicians who treated the child with SCFE was evaluated.

RESULTS

The intraclass correlation coefficient (ICC) confidence interval (CI) between the two experienced observers and the reporting clinicians overlapped for the three methods. In 37% of the cases, the difference was more than 5° between the experienced observers' measurement and the reported value by clinicians. The two experienced orthopaedists' intra- and inter-observer variability was low.

CONCLUSION

The observer's experience is more important than the method of choice when measuring the slip angle in SCFE. The research group recommends the calcar femorale method due to its feasibility on the versatile and commonly used frog leg lateral view.

Для цитирования: Lindell Mikael, Nilsson Jens, Herngren Bengt, Örtegren Jakob, Stenmarker Margaretha, Tiderius Carl Johan, Michno Piotr. Comparison of different radiographic methods to measure the slip angle in children with slipped capital femoral epiphysis (SCFE).. Acta radiologica (Stockholm, Sweden : 1987). 2024. DOI: 10.1177/02841851241271999.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.