INTRODUCTION

Dynamic stabilization of the spine has been performed since the 1990s with the double purpose of restoring spinal segmental stability and allowing residual movement at the operated level. When we take into account the different motion-preserving devices and the spinal areas where they are applied, we can identify three categories of spinal implants: anterior cervical, anterior lumbar, and posterior lumbar. However, as in all prosthetic procedures performed in orthopedic surgery, the life span of a joint replacement device is a central topic of discussion, and this is true also for spinal dynamic devices, being revision surgery a complex procedure in specific cases.

MATERIALS AND

METHODS

We performed a literature review on the different dynamic spinal implants and the most common causes of failure, providing clinical cases as illustrative options for revision surgery.

RESULTS

The review of the literature showed a 11.3% to 22.6% revision rate in posterior lumbar dynamic systems, with a peak of 40.6% in case of adjacent segment disease. In lumbar TDRs, infection and severe dislocations are the most frequent causes of anterior revisions, while posterior pedicle screw fixation could be a suitable option in minimal subsidence or TDR displacement. An algorithm for the planning of revision surgery is proposed.

CONCLUSIONS

Surgical revision of spinal dynamic implants could be a demanding surgery especially in anterior approaches. Anterior cervical revision remains globally safe, but careful preoperative evaluation of vessels and ureter are suggested to avoid intraoperative complications in the lumbar spine. In posterior revision, a proper sagittal alignment of the spine should be restored. These slides can be retrieved under Electronic Supplementary Material.

Для цитирования: Cecchinato R, Bourghli A, Obeid I. Revision surgery of spinal dynamic implants: a literature review and algorithm proposal.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2020. DOI: 10.1007/s00586-019-06282-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.