DOI 10.3928/0147-7447-19890201-08
Медицинская библиотека · Orthopedics · 1989
Slipped capital femoral epiphysis. Results of treatment with a single cannulated screw.
Клинический случайСтатьяПеревод в очереди
Аннотация
Thirty patients with 36 slipped capital femoral epiphysis underwent pinning with a single cannulated screw. All patients were pinned in situ, allowed immediate weight bearing as tolerated, discontinued crutches at 6 weeks, and had a minimum of 1 year follow up (average 21 months). One patient had avascular necrosis, one patient had bilateral chondrolysis, and two patients required repinning.
Для цитирования: Mann D, Weddington J. Slipped capital femoral epiphysis. Results of treatment with a single cannulated screw.. Orthopedics. 1989. DOI: 10.3928/0147-7447-19890201-08.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.