MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-023-03521-1

Медицинская библиотека · Journal of orthopaedic surgery and research · 2023

A novel nanohydroxyapatite/polyamide-66 cage for reducing the subsidence rate after single-level anterior cervical discectomy and fusion: a comparative study of 7-year follow-up.

Zeng Zhimou, Zhu Ce, Deng Zhipeng, Liu Limin, Song Yueming

СтатьяПеревод в очереди

Аннотация

BACKGROUND

A novel nanohydroxyapatite/polyamide-66 cage (n-HA/PA66 cage) with a horseshoe shape was designed to lower the subsidence rate of the traditional hollow cylindrical n-HA/PA66 cage. However, no studies have compared the incidence of subsidence in the two cages. The purpose of this study was to compare the long-term clinical and radiological outcomes of the novel n-HA/PA66 cage with the hollow cylindrical n-HA/PA66 cage after anterior cervical discectomy and fusion (ACDF) to treat single-level cervical degenerative disk disease (CDDD).

METHODS

Fifty-two patients with novel n-HA/PA66 cages (Group A) and fifty-five patients with hollow cylindrical n-HA/PA66 cages (Group B) were included. The radiological parameters included intervertebral height (IH), C2-7 angle (C2-7a), segmental alignment (SA), subsidence rate, and fusion rate. The clinical outcomes were visual analog scale (VAS) scores, Japanese Orthopedic Association (JOA) scores, and patient satisfaction rates.

RESULTS

The pre- and postoperative SA, C2-7a, and fusion rates of the patients in Groups A and B were similar. The preoperative and 6-month postoperative IHs in both groups were comparable. However, the final follow-up IH in Group B was significantly smaller than that in Group A (35.9 mm vs. 36.7 mm). The difference in the subsidence rates at the final follow-up between Group A (5.8%, 3/52) and Group B (18.2%, 10/55) was significant. The VAS score, JOA score, and patient satisfaction rate were not significantly different.

CONCLUSIONS

The novel n-HA/PA66 cage had similar favorable SA, C2-7a, fusion rate, and clinical outcomes compared to the hollow cylindrical n-HA/PA66 cage for treating single-level ACDF. Moreover, the novel n-HA/PA66 cage achieved a lower subsidence rate and higher IH than the hollow cylindrical n-HA/PA66 cage at the final follow-up.

Для цитирования: Zeng Zhimou, Zhu Ce, Deng Zhipeng, Liu Limin, Song Yueming. A novel nanohydroxyapatite/polyamide-66 cage for reducing the subsidence rate after single-level anterior cervical discectomy and fusion: a comparative study of 7-year follow-up.. Journal of orthopaedic surgery and research. 2023. DOI: 10.1186/s13018-023-03521-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.