DOI 10.1097/01.ta.0000051933.83342.e4
Fusion of the septic ankle: experience with 15 cases using hybrid external fixation.
Аннотация
BACKGROUND
In cases of septic joint destruction, an unfavorable situation of soft tissues and chronic osteomyelitis are responsible for high failure rates of ankle fusions. We wanted to evaluate the control of infection and the fusion rate using hybrid external fixators for the fusion of the septic ankle in a prospective study.
METHODS
From 1996 to 1998, 15 arthrodeses were performed using hybrid external fixators. All patients had a combination of bone and soft tissue infections. Fourteen patients suffered from sequelae of posttraumatic osteoarthritis, and one patient suffered from rheumatoid arthritis. In 14 patients, pathogens could be identified; in 87%, Staphylococcus aureus was found. Eight patients had relevant concomitant diseases.
RESULTS
The preservation of limbs by solid tibiotalar fusion was achieved in 14 patients (93%). One patient maintained an infected pseudarthrosis. During the 12-month follow-up, three patients had a fistula that persisted, with two patients having a solid arthrodesis. Full weight-bearing was possible for all the patients with a successful fusion. Seventy-five percent of the patients that had not retired at the time of the study regained their fitness for work.
CONCLUSION
The hybrid external fixator presents a successful alternative for those arthrodeses of ankle joints where complications such as bone/joint infections or poor soft tissue conditions occur.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.