Spondyloarthritis Research Consortium of Canada Scoring System for Sacroiliitis in Juvenile Spondyloarthritis/Enthesitis-related Arthritis: A Reliability, Validity, and Responsiveness Study.

Panwar Jyoti, Tse Shirley M L, Lim Lillian, Tolend Mirkamal A, Radhakrishnan Shilpa, Salman Muayad, Moineddin Rahim, Doria Andrea S, Stimec Jennifer

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Intra- and interreader reliability, construct validity, and responsiveness of the Spondyloarthritis Research Consortium of Canada (SPARCC) magnetic resonance imaging (MRI) scoring system were investigated for scoring sacroiliitis in patients with juvenile spondyloarthritis (JSpA)/enthesitis-related arthritis (ERA) who have received biologic and/or nonbiologic treatment.

METHODS

Ninety whole-body MRI examinations with dedicated oblique coronal planes of the sacroiliac joints in 46 patients were independently reviewed and scored by 2 pediatric musculoskeletal radiologists, blinded to clinical details, using the SPARCC system. Intra- and interreader reliability was assessed by intraclass correlation coefficients (ICC). Construct validity testing was done by (1) correlating the SPARCC MRI scores of sacroiliitis with clinical disease activity indicators (cross-sectional validity), and (2) correlating the change in the MRI score with the change in clinical indicators before and after treatment (longitudinal validity). Responsiveness of the MRI and clinical indicators was also evaluated, grouped by biologic and nonbiologic treatment.

RESULTS

When applied in children with JSpA/ERA, the SPARCC showed almost perfect intra- and interreader reliability (ICC 0.79-1.00). There was poor cross-sectional and longitudinal correlation between clinical assessment indicators and MRI scoring. SPARCC scores showed higher responsiveness to treatment-related change than most clinical outcome measures. Three clinical outcome measures correlated longitudinally with SPARCC score in nonbiologic treatment: active joint count (r = 0.72, p < 0.001), FABER (Flexion, Abduction, External Rotation) test (r = 0.58, p = 0.012), and physician's global assessment (r = 0.61, p = 0.034).

CONCLUSION

The SPARCC MRI scoring system is a reliable tool with relatively higher responsiveness than clinical indicators and is suitable for objective quantification of sacroiliitis when applied to pediatric patients with JSpA/ERA.

Для цитирования: Panwar Jyoti, Tse Shirley M L, Lim Lillian, Tolend Mirkamal A, Radhakrishnan Shilpa, Salman Muayad, Moineddin Rahim, Doria Andrea S, Stimec Jennifer. Spondyloarthritis Research Consortium of Canada Scoring System for Sacroiliitis in Juvenile Spondyloarthritis/Enthesitis-related Arthritis: A Reliability, Validity, and Responsiveness Study.. The Journal of rheumatology. 2019. DOI: 10.3899/jrheum.180222.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.