MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.biortech.2026.134537

Медицинская библиотека · Bioresource technology · 2026

Simultaneous removal of Se(IV) and Cr(VI) from acidic wastewater using a Se(IV)-reducing internal circulation reactor: performance and microbial resistance mechanisms.

Yan Su, Han Qirun, Chen Liangyu, Jin Decheng, Lu Yi, Zhou Jun, Zhang Xueying

СтатьяПеревод в очереди

Аннотация

Acidic wastewater contaminated with selenite (Se(IV)) and chromate (Cr(VI)) poses elevated environmental risks due to the combined toxicity of metal(liod) and acidity. Metal(loid)-resistant consortia, such as Se(IV)-reducing sludge (SeRS), provide a promising strategy for treating such wastewater by converting Se(IV) and Cr(VI) into less toxic Se(0) and Cr(III), respectively. In this study, an internal circulation (IC) reactor packed with SeRS and granular activated carbon was constructed to evaluate its performance in treating such wastewater. In the absence of Cr(VI), the reactor achieved Se(IV) removal efficiencies of 94.6-98.5% at influent pH values of 4.5-8.0 and Se(IV) concentrations of 1-3 mM. At an optimal pH 5.5, nearly complete removal of both oxyanions was achieved at Se(IV)/Cr(VI) molar ratios of 5.2-10.4. Alkalinity generated from acetate oxidation buffered the influent acidity at influent pH values of 4.5-5.5, thereby sustaining microbial activity. Cr(VI) stress selectively enriched Brucella, Trichlorobacter, and Seleniivibrio for Cr(VI) reduction, while Pseudomonas accounted for Se(IV) and Cr(VI) reduction. Integrated extracellular polymeric substances (EPS), glutathione reductase (GOR), and metagenomic analyses revealed that microbial resistance to Cr(VI) stress likely relied on intracellular glutathione-related detoxification, enzymatic Se(IV)/Cr(VI) reduction and antioxidant defenses, while extracellular EPS protection declined. Overall, it was demonstrated that the developed IC reactor process enabled robust and efficient removal of both Se(IV) and Cr(VI) from acidic wastewater.

Для цитирования: Yan Su, Han Qirun, Chen Liangyu, Jin Decheng, Lu Yi, Zhou Jun, Zhang Xueying. Simultaneous removal of Se(IV) and Cr(VI) from acidic wastewater using a Se(IV)-reducing internal circulation reactor: performance and microbial resistance mechanisms.. Bioresource technology. 2026. DOI: 10.1016/j.biortech.2026.134537.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.