Edge-Enabled Real-Time Gait Assessment for Degenerative Spinal Disease Using Wearable Inertial Sensors.

Wen Kuei-Ann, Lin Li-Hsieh, Yan Jiun-Lin, Chang Chen-Nen, Shih David

СтатьяПеревод в очереди

Аннотация

Gait analysis is used in the diagnosis, rehabilitation, and longitudinal monitoring of degenerative spinal disease (DSD). However, conventional gait assessment commonly depends on subjective visual observation or laboratory-based motion-capture systems, which restrict accessibility and routine clinical use. This study presents an edge-enabled real-time gait analysis framework for DSD using two ankle-worn inertial measurement units (IMUs). The proposed framework integrates causal gait-event detection with spatiotemporal gait estimation, including stride length, stride height, stride frequency, and swing ratio, across Regular-, Toe-, Heel-, and Tandem-Walk tasks. To improve the stability of wearable gait estimation, the framework incorporates a cycle-wise initial sensor-orientation correction strategy with inter-cycle horizontal velocity continuity, reducing reliance on conventional zero-velocity update (ZUPT) resetting. A percentile-referenced, separability-weighted composite score was also developed to combine average gait performance, step-to-step variability, and gait asymmetry into an interpretable clinical index. Algorithm validation was conducted using an optical motion-capture system as the reference standard. The proposed framework, however, is intended for deployment using ankle-worn IMUs and edge-based computation without requiring optical cameras, reflective markers, or dedicated motion-capture laboratories during routine operation. Experimental results showed centimeter-level spatial estimation accuracy. The composite scoring framework achieved accuracy/F1-scores of 0.971/0.981 for Regular-Walk, 0.934/0.956 for Toe-Walk, 0.955/0.970 for Heel-Walk, and 0.876/0.919 for Tandem-Walk. Feature analysis indicated that stride length, stride frequency, swing ratio, and step-to-step variability provided the greatest discrimination between healthy controls and spinal patients, with stronger group separation observed in Regular-, Toe-, and Heel-Walk tasks. These results suggest that ankle-mounted IMU sensing combined with lightweight edge-based computation and interpretable gait scoring may provide a practical approach for point-of-care gait assessment and remote functional monitoring in DSD. The proposed system operates using only two ankle-mounted IMUs during routine deployment, while optical motion capture was employed exclusively as a laboratory reference for validation.

Для цитирования: Wen Kuei-Ann, Lin Li-Hsieh, Yan Jiun-Lin, Chang Chen-Nen, Shih David. Edge-Enabled Real-Time Gait Assessment for Degenerative Spinal Disease Using Wearable Inertial Sensors.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26144339.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.