DOI 10.1097/prs.0000000000008870

Медицинская библиотека · Plastic and reconstructive surgery · 2022

Surgical and Nonsurgical Factors Associated with Salvaging Exposed Vertical Expandable Prosthetic Titanium Rib Hardware.

Kalmar Christopher L, Zapatero Zachary D, Lott Carina, Kosyk Mychajlo S, Cahill Patrick J, Swanson Jordan W, Anari Jason B, Taylor Jesse A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vertical expandable prosthetic titanium rib (VEPTR) devices were designed to treat childhood scoliosis and thoracic insufficiency syndrome. Although they have drastically reduced patient mortality, they present a profound subcutaneous hardware burden. The authors examined the surgical and nonsurgical factors associated with salvage of VEPTR hardware exposures.

METHODS

Between 2014 and 2020, a prospective institutional database was queried for patients with VEPTR hardware complications who required soft-tissue reconstruction. Hardware salvage was considered successful if reconstruction allowed the hardware to be retained until the next VEPTR expansion.

RESULTS

Fifty-eight patients required VEPTR hardware salvage. Hardware complications were successfully salvaged in 62.1 percent of patients at 60.0 percent of operative sites. Neuromuscular scoliosis (p = 0.041) and nonambulatory status (p = 0.018) were factors associated with VEPTR hardware salvage failure, whereas congenital scoliosis was associated with successful hardware salvage (p = 0.012) and preventing need for immediate hardware removal (p = 0.049). Exposed hardware, as compared to threatened exposure, was more likely to require immediate removal (p = 0.045) and result in unsuccessful hardware salvage (p = 0.015).

CONCLUSIONS

Local and regional muscle flaps were able to prevent VEPTR hardware removal in the majority of patients, even in the setting of infection, immobility, incontinence, and multiple systemic comorbidities. Patients with neuromuscular scoliosis and nonambulatory status were at increased risk for failure, whereas those with incontinence and low body mass index trended toward increased risk of failure. Threatened exposure was associated with higher rates of salvage than exposed hardware, and thus earlier referral to plastic surgeons for soft-tissue salvage may be advised.

CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.

Для цитирования: Kalmar Christopher L, Zapatero Zachary D, Lott Carina, Kosyk Mychajlo S, Cahill Patrick J, Swanson Jordan W, Anari Jason B, Taylor Jesse A. Surgical and Nonsurgical Factors Associated with Salvaging Exposed Vertical Expandable Prosthetic Titanium Rib Hardware.. Plastic and reconstructive surgery. 2022. DOI: 10.1097/prs.0000000000008870.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.