MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medsci14020236

Медицинская библиотека · Medical sciences (Basel, Switzerland) · 2026

Test-Retest Reliability of a Performance-Based Test Battery in Patients with Fibromyalgia According to Socio-Occupational Status.

Socorro-Cumplido José Luis, Roman-Viñas Blanca, Almirall Miriam, Sánchez-Raya Judith, Blanch-Rubió Josep, Castro Maria José, Giné-Garriga Maria, Launois Patricia, Araya Tamara Libertad Rodríguez, Gassol Anna Arias, Milà Villarroel Raimon, Chaler Joaquim

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Performance-based tests (PBTs) objectively assess functional capacity and are increasingly applied in fibromyalgia (FM) to complement patient-reported outcomes (PROMs). However, evidence regarding their reliability, especially considering patients' socio-occupational status, is limited. This study aimed to determine test-retest reliability of a standardized PBT battery in women with FM and to examine the influence of employment status on measurement stability.

METHODS

A total of 119 women were assessed (89 with FM). The battery included the 6 min walk test (6MWT), handgrip strength test (HST), and 8 feet up and go test (8FUGT). Test-retest reliability was examined using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest real difference (SRD). Analyses were conducted for the total FM group and socio-occupational subgroups (actively working, claiming disability, and permanent disability).

RESULTS

All PBTs demonstrated excellent test-retest reliability. Measurement stability was consistently higher in controls. Absolute reliability indices confirmed acceptable measurement stability. However, the claiming disability group showed markedly higher SEM% and SRD% for HST, suggesting reduced reproducibility. The 6MWT and 8FUGT maintained excellent reliability and stability across all groups. PROMs showed good-to-excellent reliability.

CONCLUSIONS

PBTs showed excellent reliability in women with FM. However, reliability varied across socio-occupational groups, particularly for HST in patients claiming disability. PROMSs showed lower reliability than PBTs.

Для цитирования: Socorro-Cumplido José Luis, Roman-Viñas Blanca, Almirall Miriam, Sánchez-Raya Judith, Blanch-Rubió Josep, Castro Maria José, Giné-Garriga Maria, Launois Patricia, Araya Tamara Libertad Rodríguez, Gassol Anna Arias, Milà Villarroel Raimon, Chaler Joaquim. Test-Retest Reliability of a Performance-Based Test Battery in Patients with Fibromyalgia According to Socio-Occupational Status.. Medical sciences (Basel, Switzerland). 2026. DOI: 10.3390/medsci14020236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.