MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/01477447-20250827-01

Медицинская библиотека · Orthopedics · 2025

Comparison of Hounsfield Unit Value and Vertebral Bone Quality Score in Predicting Cage Subsidence After Zero-P Fusion Surgery.

Pu Hong-Yu, Wang Jin-Zhou, Guo Jian-Wei, Luo Shi-Wu, Yu Jun-Dong, Zeng Rui

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

This study compared the predictive performance of the Hounsfield unit (HU) value and vertebral bone quality (VBQ) score based on cage subsidence after anterior cervical discectomy and Zero-P fusion.

MATERIALS AND

METHODS

We conducted a retrospective analysis of 104 patients who underwent Zero-P fusion surgery for cervical spondylosis in our hospital. Before surgery, the VBQ of each patient's C2-C7 vertebral body was measured by cervical magnetic resonance imaging, while the HU value was measured by cervical computed tomography. The maximum loss distance of vertebral height was measured immediately after surgery and at final follow-up. Patients were divided into a subsidence group (≥3 mm) and a non-subsidence group (<3 mm). Single-factor analysis was used to preliminarily determine the risk factors for Zero-P cage (ZPC) subsidence. For variables with statistical differences, logistic regression was further used for multivariate analysis to determine independent risk factors. Receiver operating characteristic (ROC) and area under the curve (AUC) were used to evaluate the ability of VBQ score and HU value to predict ZPC subsidence.

RESULTS

Interbody ZPC subsidence was observed in 20 of 104 patients. Significant differences in HU value and VBQ score were found between the two groups. HU value (odds ratio [OR]=0.987, 95% CI 0.978-0.997, P=0.006) and VBQ score (OR=4.462, 95% CI 1.721-11.373, P=0.002) were independent risk factors for ZPC subsidence. On the ROC curve, the AUC of VBQ score was 0.776 (95% CI 0.669-0.883), and the optimal threshold of VBQ score was 3.860 (sensitivity: 60.0%, specificity: 86.9%). The AUC of HU was 0.757 (95% CI 0.645-0.869), and the optimal threshold of HU value was 298.44 (sensitivity: 60.7%, specificity: 90.0%). The AUC of HU value and VBQ score showed no statistical difference, whereas the AUC of the joint index of HU value and VBQ score was 0.833, which was higher than that of the single indicator, and the difference was statistically significant (P<0.05).

CONCLUSION

Higher VBQ score and lower HU value are independent predictors of ZPC subsidence in patients following Zero-P fusion. The joint index of HU value and VBQ score is more predictive of Zero-P fusion than a single indicator.

Для цитирования: Pu Hong-Yu, Wang Jin-Zhou, Guo Jian-Wei, Luo Shi-Wu, Yu Jun-Dong, Zeng Rui. Comparison of Hounsfield Unit Value and Vertebral Bone Quality Score in Predicting Cage Subsidence After Zero-P Fusion Surgery.. Orthopedics. 2025. DOI: 10.3928/01477447-20250827-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.