US depiction of partial-thickness tear of the rotator cuff.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
van Holsbeeck M T, Kolowich P A, Eyler W R, Craig J G, Shirazi K K, Habra G K, Vanderschueren G M, Bouffard J A
Аннотация
PURPOSE: To test previously defined ultrasound (US) criteria for identification of partial-thickness tears of the rotator cuff.
MATERIALS AND METHODS: Before shoulder arthroscopy, 52 patients with shoulder pain for more than 3 months were examined with a 7.5-MHz commercially available linear-array transducer and a standardized study protocol. The criteria used to detect partial-thickness tears were (a) a mixed hyper- and hypoechoic focus in the crucial zone of the supraspinatus tendon and (b) a hypoechoic lesion visualized in two orthogonal imaging planes with either articular or bursal extension.
RESULTS: The US findings were reported as partial-thickness tears in 17 shoulders, of which three were false-positive findings. There was one false-negative finding. The sensitivity of US in depiction of partial-thickness tears was 93%, and specificity was 94%. The positive predictive value was 82%, and the negative predictive value was 98%.
CONCLUSION: US can depict most partial-thickness tears with use of the criteria described.
MATERIALS AND METHODS: Before shoulder arthroscopy, 52 patients with shoulder pain for more than 3 months were examined with a 7.5-MHz commercially available linear-array transducer and a standardized study protocol. The criteria used to detect partial-thickness tears were (a) a mixed hyper- and hypoechoic focus in the crucial zone of the supraspinatus tendon and (b) a hypoechoic lesion visualized in two orthogonal imaging planes with either articular or bursal extension.
RESULTS: The US findings were reported as partial-thickness tears in 17 shoulders, of which three were false-positive findings. There was one false-negative finding. The sensitivity of US in depiction of partial-thickness tears was 93%, and specificity was 94%. The positive predictive value was 82%, and the negative predictive value was 98%.
CONCLUSION: US can depict most partial-thickness tears with use of the criteria described.