MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2018.10.008

Медицинская библиотека · Academic radiology · 2018

Usefulness of MR Arthrography of the Hip with and without leg Traction in Detection of Intra-articular Bodies.

Schmaranzer F, Lerch T D, Strasser U, Vavron P, Schmaranzer E, Tannast M

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVE

Although intra-articular bodies are a classic indication for MR arthrography and surgical removal, diagnostic studies are currently sparse. To assess the diagnostic performance of MR arthrography with and without leg traction in detection of intra-articular bodies in the hip joint.

MATERIAL AND

METHODS

The institutional hip arthroscopy data base (2009-2016: 631 hips) was retrospectively reviewed. Inclusion criteria were hips with and without intra-articular bodies and direct MR arthrography performed with and without leg traction. Twenty-one hips with intra-articular bodies constituted the "disease-positive" group. Seventy-nine randomly selected hips without intra-articular bodies constituted the "disease-negative" group. Images were reviewed independently for presence of intra-articular bodies by two blinded readers. Overall diagnosis and location of intra-articular bodies was recorded (peripheral or central). Arthroscopy served as goldstandard for diagnosis and location of intra-articular bodies. Diagnostic performance and kappa statistics of traction MR arthrography with and without traction were calculated.

RESULTS

For both readers sensitivity/specificity of traction MR arthrography was 86%-95% respectively 90%-91% for overall diagnosis of intra-articular bodies and was 81%-86% respectively 90%-92%for MR arthrogrpahy without traction. For central intra-articular bodies sensitivity was higher for both readers with traction (79%-89%) than without traction (74% each).

CONCLUSION

MR arthrography with and without traction of the hip is highly accurate in identifying central and peripheral intra-articular bodies. Application of traction was further useful for visualization of centrally located intra-articular bodies.

Для цитирования: Schmaranzer F, Lerch T D, Strasser U, Vavron P, Schmaranzer E, Tannast M. Usefulness of MR Arthrography of the Hip with and without leg Traction in Detection of Intra-articular Bodies.. Academic radiology. 2018. DOI: 10.1016/j.acra.2018.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.