C- VBQ versus CT Hounsfield units in predicting cage subsidence following ACDF: a retrospective cohort analysis.

Li Yuanpeng, Chen Lu, Shen Sinuo, Shi Hang, Jiang Zanli, Zhu Lei

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To compare the efficacy of MRI-based cervical vertebral bone quality score (C-VBQ) and CT-based cervical Hounsfield units (C-HU) in predicting cage subsidence after anterior cervical discectomy and fusion (ACDF), and to explore related risk factors.

METHODS

A total of 125 patients (209 surgical segments) who underwent 1- to 3-level ACDF in our institution from January 2019 to December 2023 were retrospectively enrolled. Baseline data, radiographic parameters (C-VBQ, C-HU, T1 slope, cervical Cobb angle, segmental angle, etc.), and surgical information of the patients were collected. Cage subsidence was defined as a loss of surgical segment height ≥ 3 mm (ΔH ≥ 3 mm) at the last follow-up compared with immediately after surgery. Differences between the subsidence group and non-subsidence group were compared. Binary Logistic regression analysis was used to identify independent risk factors for patient-level subsidence, while generalized estimating equations and linear regression were applied to analyze factors related to segment-level subsidence height. The predictive efficacy of C-VBQ and C-HU was evaluated using ROC curves.

RESULTS

The incidence of patient-level subsidence was 36%. Patients in the subsidence group were older (P < 0.0001), with significantly higher C-VBQ scores (P < 0.0001) and significantly lower C-HU values (P < 0.0001) compared to the non-subsidence group. Multivariate Logistic regression showed that C-VBQ (OR = 1.61) and number of surgical levels (OR = 2.45) were independent predictors of patient-level subsidence, with a model prediction accuracy of 83.2%. C-HU (OR = 0.98) and number of surgical levels (OR = 1.97) were also independent predictors, with a prediction accuracy of 76.8%. ROC curve analysis revealed that the AUC of C-VBQ for predicting subsidence (0.873) was superior to that of C-HU (0.833). Segmental-level analysis showed that the intraoperative traction height of subsided segments was significantly greater than that of non-subsided segments (P = 0.009). Linear regression model indicated that C-VBQ (β = 1.974, P < 0.001) and traction height (β = 0.166, P < 0.001) were significant positive predictors of subsidence height ΔH (R²=0.427). A significant negative correlation was observed between C-VBQ and C-HU (r=-0.800, P < 0.001).

CONCLUSION

Both C-VBQ score and C-HU value are significantly associated with cage subsidence after ACDF. C-VBQ is a robust indicator for predicting subsidence after multi-level ACDF, with better independent predictive efficacy and higher specificity than C-HU. An increased number of surgical levels, particularly three-level procedures, significantly elevated the risk of subsidence. Excessively high intraoperative traction height is an independent risk factor for subsidence magnitude. C-VBQ score provides a radiation-free and low-cost method for evaluating bone quality, and when combined with C-HU, it can serve as an important tool for preoperative risk stratification in ACDF.

Для цитирования: Li Yuanpeng, Chen Lu, Shen Sinuo, Shi Hang, Jiang Zanli, Zhu Lei. C- VBQ versus CT Hounsfield units in predicting cage subsidence following ACDF: a retrospective cohort analysis.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2025. DOI: 10.1007/s00586-025-09464-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.