MedElevator Войти в исследования
← Поиск публикаций

DOI 10.26355/eurrev_202202_27993

Медицинская библиотека · European review for medical and pharmacological sciences · 2022

The magnetic resonance imaging assessment of optic nerve sheath diameter in pediatric acute liver failure patients.

Doğan G M, Siğirci A, Okut G, Cicek E, Dogan S M, Yilmaz S, Arslan A K

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the diagnostic value of optic nerve sheath diameter (ONSD) using brain MRI in the pretransplantation period in the pediatric acute liver failure patients, and correlate the ONSD with clinical grade of hepatic encephalopathy (HE) and MRI findings.

PATIENTS AND

METHODS

Forty acute liver failure patients and 40 control group patients were retrospectively analyzed. The high signal intensities in T2W (T2-weighted image), FLAIR (Fluid Attenuated Inversion Recovery) and DWI (diffusion-weighted imaging) sequences were evaluated and ONSD was measured. The patients were grouped first into 5 according to their West Haven score, and HE grade 0 and grade 1 were accepted as low grade HE, HE grade 2, 3 and 4 were accepted as high grade HE. The patients were grouped to 2 according to the MRI findings as low grade and high grade MRI group.

RESULTS

The mean value of ONSD was 6.0 ± 1.80 and 4.94 ± 1.27 in the all patients and in the control group, respectively. There was statistically significant difference between both the ONSD and the low grade-high grade HE groups (p=0.01), and between the ONSD and the low grade-high grade MRI groups (p<0.001).

CONCLUSIONS

Although high ONSD values do not make the diagnosis of cerebral edema, it may cause suspicion in the early period. MRI can be helpful in the diagnoses of increased intracranial pressure like ultrasound. Our study is the first study to compare ONSD and MRI findings in addition to HE grades. The widespread use of MRI in children in recent years may help determine the normal range of ONSD values.

Для цитирования: Doğan G M, Siğirci A, Okut G, Cicek E, Dogan S M, Yilmaz S, Arslan A K. The magnetic resonance imaging assessment of optic nerve sheath diameter in pediatric acute liver failure patients.. European review for medical and pharmacological sciences. 2022. DOI: 10.26355/eurrev_202202_27993.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.