MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-024-04102-6

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024

The acetabularization index: a novel measure of acromial bone loss prior to reverse shoulder arthroplasty.

Shekhbihi Abdelkader, Moroder Philipp, Abdalla Abdelhady, Reichert Winfried, Scheibel Markus, Masoud Mohammad

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Acromial stress fractures following reverse shoulder arthroplasty (RSA) have gained attention among specialized surgeons over the past decades craving answers regarding predisposing factors and technical aspects as how to avoid the complication. This study introduces the acetabularization index (AI) for the preoperative estimation of acromial bone loss attributed to acetabularization in cases of cuff tear arthropathy (CTA).

METHODS

The acromiohumeral interval (AHI), extent of acromial acetabularization (AA), acromial height (AH), and width of acetabularization (r) were measured on preoperative radiographs and two-dimensional computed tomography scans (2D CT) of patients who underwent RSA within the timeline 2019-2023 for CTA. The AI calculated AI % = AA mm ÷ AH mm . The CTA grade was determined according to the Hamada classification. The AI values on radiographs and 2D CT were compared by a Student's t-test. Possible correlation between the AI and AHI was investigated via Pearson's coefficient. The intraclass correlation coefficient (ICC) was employed to test the interobserver reliability among two independent testers.

RESULTS

The radiographs and 2D CT scans of thirty-three patients who underwent RSA were analyzed. The mean AHI, AH, AA, r, and AI values on radiographs were 5.5 ± 2 mm, 10 ± 2 mm, 2 ± 2 mm, 30 ± 4 mm, 16 ± 16%, respectively. On 2D CT, the corresponding mean values were 4.7 ± 2.5 mm, 10.8 ± 2.65 mm, 2.45 ± 2.35 mm, and 30 ± 4.5, and 22.3 ± 22%, respectively. There was a statistically significant difference between the AI values on radiographs and 2D CT (P = .000). The Pearson's correlation coefficient demonstrated a negative correlation between AI and AHI (r = - 0.33). Excellent reliability was observed by the ICC values for all parameters in both groups among two testers.

CONCLUSION

The AI is a reliably measurable tool on radiographs and 2D CT scans; however, the measurements derived from radiographs vary significantly from CT based measurements due to projection restrictions. Grade IVB of the Hamada/Fukuda classification is associated with the highest AI values. Further research is warranted to assess the clinical utility of this index as a predictive tool for postoperative acromial stress fractures.

Для цитирования: Shekhbihi Abdelkader, Moroder Philipp, Abdalla Abdelhady, Reichert Winfried, Scheibel Markus, Masoud Mohammad. The acetabularization index: a novel measure of acromial bone loss prior to reverse shoulder arthroplasty.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2024. DOI: 10.1007/s00590-024-04102-6.