MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0268-0033(00)00063-2

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2001

Intervertebral disc herniation: studies on a porcine model exposed to highly repetitive flexion/extension motion with compressive force.

Callaghan J P, McGill S M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine whether repeated motion with low magnitude joint forces, and flexion/extension moments consistently produce herniation in a non-degenerated, controlled porcine spine motion segment.

DESIGN

Combined loading (flexion/extension motions and compressive forces) was applied to in vitro porcine functional spinal units. Biomechanical and radiographic characteristics were documented.

BACKGROUND

While most studies performed in vitro have examined uniaxial or fixed position loading to older specimens, there have been few studies that have examined whether 'Работает' intervertebral discs can be injured by low magnitude repeated combined loading.

METHODS

Porcine cervical spine motion segments (C3-C4) were mounted in a custom jig which applied axial compressive loads with pure flexion/extension moments. Dynamic testing was conducted to a maximum of 86400 bending cycles at a rate of 1 Hz with simultaneous torques, angular rotations, axial deformations recorded for the duration of the test.

RESULTS

Herniation (posterior and posterior-lateral regions of the annulus) occurred with relatively modest joint compression but with highly repetitive flexion/extension moments. Increased magnitudes of axial compressive force resulted in more frequent and more severe disc injuries.

CONCLUSIONS

The results support the notion that intervertebral disc herniation may be more linked to repeated flexion extension motions than applied joint compression, at least with younger, non-degenerated specimens. Relevance. While intervertebral disc herniations are observed clinically, consistent reproduction of this injury in the laboratory has been elusive. This study was designed to examine the biomechanical response and failure mechanics of spine motion segments to highly repetitive low magnitude complex loading.

Для цитирования: Callaghan J P, McGill S M. Intervertebral disc herniation: studies on a porcine model exposed to highly repetitive flexion/extension motion with compressive force.. Clinical biomechanics (Bristol, Avon). 2001. DOI: 10.1016/s0268-0033(00)00063-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.