Goldbloom Daniel, Makwana Nilesh, Laing Patrick, Toullec Eric, Graff Wilfrid, Charbel Antoine
Аннотация
BACKGROUND: Proximal osteotomy of the first metatarsal is often indicated for Hallux Valgus correction. Previously recognised complications however, include transfer metatarsalgia, first metatarsophalangeal joint stiffness, problems with fixation and prominence of metalware.
METHODS: We report on one year follow up of an international prospective series between June 2009 and October 2012 involving three centres, including 91 feet (58 patients) that underwent proximal osteotomy, using a new locking plate applied to the plantar surface of the metatarsal.
RESULTS: Mean Hallux Valgus angle improved from 27.9 (±13.1)° to 12.4 (±8.2)° while mean Intermetatarsal angle improved from 12.5 (±8.4) to 7.1 (±3.4) and there was a statistically significant improvement in both mean AOFAS-HMI score 54.2 (±13.9) to 94.0 (±9.5) and Visual Analogue Pain Scale 4.7 (±1.5) to 0.6 (±1.3). 70% of patients were back at their preoperative employment at five weeks. Mean surgical time was 56min and the plate was generally well tolerated. There were five implant related complications.
CONCLUSIONS: Locked fixation from the tension side of the construct encourages early weight bearing with a low risk of implant prominence. Our radiological, functional and clinical parameters are comparable with similar series and we therefore recommend this technique.
METHODS: We report on one year follow up of an international prospective series between June 2009 and October 2012 involving three centres, including 91 feet (58 patients) that underwent proximal osteotomy, using a new locking plate applied to the plantar surface of the metatarsal.
RESULTS: Mean Hallux Valgus angle improved from 27.9 (±13.1)° to 12.4 (±8.2)° while mean Intermetatarsal angle improved from 12.5 (±8.4) to 7.1 (±3.4) and there was a statistically significant improvement in both mean AOFAS-HMI score 54.2 (±13.9) to 94.0 (±9.5) and Visual Analogue Pain Scale 4.7 (±1.5) to 0.6 (±1.3). 70% of patients were back at their preoperative employment at five weeks. Mean surgical time was 56min and the plate was generally well tolerated. There were five implant related complications.
CONCLUSIONS: Locked fixation from the tension side of the construct encourages early weight bearing with a low risk of implant prominence. Our radiological, functional and clinical parameters are comparable with similar series and we therefore recommend this technique.