MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/os.13102

Медицинская библиотека · Orthopaedic surgery · 2021

Correlation Analysis for Selection of Microtitanium Plates with Different Specifications for Use in a Cervical Vertebral Dome Expansion Laminoplasty.

Zhou Run-Tian, Zhao Xiao-Feng, Zhao Yi-Bo, Lu Xiang-Dong, Fan Zhi-Feng, Qi De-Tai, Wang Xiao-Nan, Jin Yuan-Zhang, Zhao Bin

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze correlations between the selection of microtitanium plates with different specifications for use in a cervical vertebral dome expansion laminoplasty.

METHODS

Sixteen patients that underwent the cervical vertebral dome expansion laminoplasty with a cervical spinal stenosis angioplasty procedure for treatment of their cervical spinal cords were recruited at our hospital. From February 2017 to September 2018, medical records confirmed that all patients underwent cervical CT and MRI tests pre- and postsurgery. The anteroposterior diameter of the spinal canal, changes in the cross-sectional area of the spinal canal, and the pre- and postsurgery distance of the cervical spinal cord after applying microtitanium plates with different lengths were measured by Mimics version 17.0 software (Materialise NV, Leuven, Belgium). A statistical regression and correlation analysis of relevant specification parameters of the microtitanium plate was then studied.

RESULTS

As the size of the microtitanium plate increased, we found that the cross-sectional area of cervical spinal canal and distance between the descendants of the lamina and the distance of cervical spinal cord concordantly increased, and these data changes linearly. The regression equation associated with sagittal diameter, cross-sectional area, and posterior movement distance of the cervical spinal cord was obtained.

CONCLUSION

According to the correlation analysis of imaging data changes, the regression equation was obtained to guide the selection of microtitanium plates with appropriate specifications in a cervical vertebral dome expansion laminoplasty.

Для цитирования: Zhou Run-Tian, Zhao Xiao-Feng, Zhao Yi-Bo, Lu Xiang-Dong, Fan Zhi-Feng, Qi De-Tai, Wang Xiao-Nan, Jin Yuan-Zhang, Zhao Bin. Correlation Analysis for Selection of Microtitanium Plates with Different Specifications for Use in a Cervical Vertebral Dome Expansion Laminoplasty.. Orthopaedic surgery. 2021. DOI: 10.1111/os.13102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.