MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-024-06258-6

Медицинская библиотека · International orthopaedics · 2024

Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.

Kobayashi Seneki, Sugano Nobuhiko, Ando Wataru, Fukushima Wakaba, Kondo Kyoko, Sakai Takashi

СтатьяМногоцентровое исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?

METHODS

Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.

RESULTS

Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.

CONCLUSIONS

Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.

LEVEL OF CLINICAL EVIDENCE: Level III, therapeutic cohort study.

Для цитирования: Kobayashi Seneki, Sugano Nobuhiko, Ando Wataru, Fukushima Wakaba, Kondo Kyoko, Sakai Takashi. Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.. International orthopaedics. 2024. DOI: 10.1007/s00264-024-06258-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.