MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s22041633

Медицинская библиотека · Sensors (Basel, Switzerland) · 2022

Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study.

Lodin Jan, Jelínek Marek, Sameš Martin, Vachata Petr

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

Lumbar spine stenosis (LSS) typically manifests with neurogenic claudication, altering patients' gait. The use of optoelectronic systems has allowed clinicians to perform 3D quantitative gait analysis to quantify and understand these alterations. Although several authors have presented analysis of spatiotemporal gait parameters, data concerning kinematic parameters is lacking. Fifteen patients with LSS were matched with 15 healthy controls. Quantitative gait analysis utilizing optoelectronic techniques was performed for each pair of subjects in a specialized laboratory. Statistical comparison of patients and controls was performed to determine differences in spatiotemporal parameters and the Gait Profile Score (GPS). Statistically significant differences were found between patient and control groups for all spatiotemporal parameters. Patients had significantly different overall GPS (p = 0.004) and had limited internal/external pelvic rotation (p < 0.001) and cranial/caudal movement (p = 0.034), limited hip extension (p = 0.012) and abduction/adduction (p = 0.012) and limited ankle plantar flexion (p < 0.001). In conclusion, patients with LSS have significantly altered gait patterns in three regions (pelvis, hip and ankle) compared to healthy controls. Analysis of kinematic graphs has given insight into gait pathophysiology of patients with LSS and the use of GPS will allow us to quantify surgical results in the future.

Для цитирования: Lodin Jan, Jelínek Marek, Sameš Martin, Vachata Petr. Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study.. Sensors (Basel, Switzerland). 2022. DOI: 10.3390/s22041633.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.