MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/xst-17341

Медицинская библиотека · Journal of X-ray science and technology · 2018

Denoising images of dual energy X-ray absorptiometry using non-local means filters.

Al-Antari Mugahed A, Al-Masni Mohammed A, Metwally Mohamed K, Hussain Dildar, Park Se-Je, Shin Jeong-Sik, Han Seung-Moo, Kim Tae-Seong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

In general, the image quality of high and low energy images of dual energy X-ray absorptiometry (DXA) suffers from noise due to the use of a small amount of X-rays. Denoising of DXA images could be a key process to improve a bone mineral density map, which is derived from a pair of high and low energy images. This could further improve the accuracy of diagnosis of bone fractures and osteoporosis.

OBJECTIVE

This study aims to develop and test a new technology to improve the quality, remove the noise, and preserve the edges and fine details of real DXA images.

METHODS

In this study, a denoising technique for high and low energy DXA images using a non-local mean filter (NLM) was presented. The source and detector noises of a DXA system were modeled for both high and low DXA images. Then, the optimized parameters of the NLM filter were derived utilizing the experimental data from CIRS-BFP phantoms. After that, the optimized NLM was tested and verified using the DXA images of the phantoms and real human spine and femur.

RESULTS

Quantitative evaluation of the results showed average 24.22% and 34.43% improvement of the signal-to-noise ratio for real high and low spine images, respectively, while the improvements were about 15.26% and 13.55% for the high and low images of the femur. The qualitative visual observations of both phantom and real structures also showed significantly improved quality and reduced noise while preserving the edges in both high and low energy images. Our results demonstrate that the proposed NLM outperforms the conventional method using an anisotropic diffusion filter (ADF) and median techniques for all phantom and real human DXA images.

CONCLUSIONS

Our work suggests that denoising via NLM could be a key preprocessing method for clinical DXA imaging.

Для цитирования: Al-Antari Mugahed A, Al-Masni Mohammed A, Metwally Mohamed K, Hussain Dildar, Park Se-Je, Shin Jeong-Sik, Han Seung-Moo, Kim Tae-Seong. Denoising images of dual energy X-ray absorptiometry using non-local means filters.. Journal of X-ray science and technology. 2018. DOI: 10.3233/xst-17341.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.