MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11657-016-0267-2

Медицинская библиотека · Archives of osteoporosis · 2016

A new implementation of digital X-ray radiogrammetry and reference curves of four indices of cortical bone for healthy European adults.

Thodberg Hans Henrik, Böttcher Joachim, Lomholt Jens, Kreiborg Sven, Wolf Gunter, Pfeil Alexander

СтатьяПеревод в очереди

Аннотация

UNLABELLED: Digital X-ray radiogrammetry performs measurements on a hand radiograph in digital form. We present an improved implementation of the method and provide reference curves for four indices for the amount of bone. We collected 1662 hand radiographs of healthy subjects of age 9-100 years.

PURPOSE: The digital X-ray radiogrammetry (DXR) method has been shown to be efficient for diagnosis of osteoporosis and for assessment of progression of rheumatoid arthritis. The aim of this work is to present a new DXR implementation and reference curves of four indices of cortical bone and to compare their relative SDs in healthy subjects at fixed age and gender.

MATERIALS AND

METHODS

A total of 1662 hand radiographs of healthy subjects of age 9-100 years were collected in Jena in 2001-2005. We also used a longitudinal study of 116 Danish children born in 1952 with on average 11 images taken over the age range 7 to 40 years. The new DXR method reconstructs the whole metacarpal contour so that the metacarpal lengths can be measured and used in two of the indices. The new DXR method automatically validates 97 % of the images and is implemented as a local server for PACS users.

RESULTS

The Danish bone health index (BHI) data are consistent with the Jena data and also with the published BHI reference for healthy children. BHI is found to have smaller relative SD than the other three indices in the Jena cohort over the age range 20-80 years.

CONCLUSION

The new DXR method is an extension of the existing BoneXpert method for children, which allows patients to be followed from childhood into adulthood with the same method. By making all four indices of cortical bone available within the same medical device, it becomes possible to decide which index has the best relation to fracture risk in future studies.

Для цитирования: Thodberg Hans Henrik, Böttcher Joachim, Lomholt Jens, Kreiborg Sven, Wolf Gunter, Pfeil Alexander. A new implementation of digital X-ray radiogrammetry and reference curves of four indices of cortical bone for healthy European adults.. Archives of osteoporosis. 2016. DOI: 10.1007/s11657-016-0267-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.