MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41467-026-73535-w

Медицинская библиотека · Nature communications · 2026

An implantable mechano-electro cascade platform synchronizes neuro-muscle repair.

Nan Liping, Cao Wentao, Fang Jiaqi, Shi Pengzhi, Jin Xuehan, Wang Jianguang, Jin Fengshan, Wang Feng, Song Kaihang, Liu Shengfu, Zhou Zifei, Wang Xu, Wang Tianlong, Chen Feng, Liu Junjian, Qian Yun

СтатьяПеревод в очереди

Аннотация

Peripheral nerve injury triggers slow axonal regeneration and irreversible muscle atrophy due to the absence of synchronous neuromuscular repair strategies. We present a fully implantable, self-powered Mechano-driven Electro-adaptable Bioelectronic Implant System (MEBIS) enabling coordinated mechanical-electrical stimulation for integrated neuromuscular regeneration. A programmable robotic actuator delivers quantifiable mechanical massage to denervated muscle, enhancing perfusion while deforming a nanogenerator that converts motion into localized electrical cues. These signals stimulate injured nerves, inducing intracellular Ca2+ elevation and Ca2+-dependent signaling, which activates downstream HIF-1α/AMPK pathways to accelerate Schwann cell activity, angiogenesis, and axonal regrowth. This mechano-electro-biochemical cascade couples muscle preservation with nerve regeneration in a closed loop, overcoming depth limitations and output instability of conventional stimulators. Validated in rat and porcine models, MEBIS significantly improves functional recovery, electrophysiology, and histomorphometry without biocompatibility concerns. Our platform establishes a scalable, feedback-controlled paradigm for precision repair and rehabilitation after peripheral nerve injury.

Для цитирования: Nan Liping, Cao Wentao, Fang Jiaqi, Shi Pengzhi, Jin Xuehan, Wang Jianguang, Jin Fengshan, Wang Feng, Song Kaihang, Liu Shengfu, Zhou Zifei, Wang Xu, Wang Tianlong, Chen Feng, Liu Junjian, Qian Yun. An implantable mechano-electro cascade platform synchronizes neuro-muscle repair.. Nature communications. 2026. DOI: 10.1038/s41467-026-73535-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.